SOI/DT 2007-02 dmm
58/66
599 38 61-92
Alarm
Possible fault
Action/machine status
Reset
E58
Motor defective; Wiring defective on inverter for motor, inverter board defective,
abnormal motor operation (motor overloaded).
Cycle stops with door locked (after 5 attempts).
RESET
E59
Motor defective; Wiring defective on inverter for motor;
Inverter board defective.
Cycle stops with door locked (after 5 attempts).
RESET
E5A
Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let appliance cool
down)
Cycle stops with door locked (after 5 attempts).
RESET
E5B
Wiring defective, Inverter board defective
Cycle stops with door locked (after 5 attempts).
RESET
E5C
Inverter board defective, the masters voltage is too high (measure the masters voltage) Cycle stops with door locked (after 5 attempts). RESET
E5D
Line interference, Wiring defective, defective main board or inverter board
Cycle stops with door locked (after 5 attempts).
RESET
E5E
Defective wiring between main board and inverter board, Defective inverter board,
defective main board.
Cycle stops
ON/OFF
E5F
Defective inverter board, Defective wiring, defective main board
Cycle stops with door locked (after 5 attempts).
RESET
E61
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
The heating phase is skipped.
START/RESET
E62
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped with door open.
RESET
E66
PCB faulty .
Safety drain cycle – Cycle stopped with door open.
RESET
E68
Earth-leakage between heater and earth.
Cycle blocked with door open.
RESET
E71
Faulty NTC sensor; Wiring faulty;
PCB faulty.
Heating is skipped.
START/RESET
E74
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty.
Heating is skipped.
START/RESET
E82
PCB faulty (Wrong configuration data). Selector, wiring
----------------
RESET
E83
PCB faulty (Wrong configuration data). Selector, wiring
Cycle cancelled.
START/RESET
E91
Wiring faulty; Faulty control/display board
PCB faulty.
---------------- RESET
E92
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted.
OFF/ON START
E93
Incorrect configuration data; PCB faulty. Cycle
interrupted.
OFF/ON
E94
Incorrect configuration data; PCB faulty. Cycle
interrupted.
OFF/ON
E95
PCB faulty.
Cycle interrupted.
RESET
E97
Faulty PCB (Wrong configuration data).
Cycle interrupted.
RESET
E98
Incompatibility between main board and Inverter Cycle
interrupted.
OFF/ON
E99
Main PCB.
Cycle interrupted.
OFF/ON
E9B
Display board.
Cycle interrupted.
Reset
E9C
Display board.
Cycle interrupted.
Reset
E9D
Display board.
Cycle interrupted.
Reset
E9F
Main PCB.
Cycle interrupted.
OFF/ON