29
Electrical connection
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should
this safety measure not be observed.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance’s
rating plate. The rating plate is located at the top of the
rim of the open door.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1363/A) fuse
must be used.
Should the plug need to be replaced for any reason,
proceed as described below.
The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
GREE
N
& YELLOW
BROW
N
CORD CLA
M
P
BLUE
13
A
P
1
04
1
E
N
L
M
o
d. ..........
Pro
d. N
o
. ...........
S
er
. N
o
. .........
M
od
. ..........
Pro
d. N
o. ...........
Se
r. N
o. .........
P0042
BD
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the
earth symbol
or coloured green and yellow.
The wire coloured blue must be connected to the
terminal «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely. Should the appliance power supply
cable neeed to be replaced, this must be carried
out by our Service Force Centre.
Note
When the appliance is installed the power supply cable
must be accessible.
Permanent connection
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.