Problem

Possible cause(s)

Solution

Does not work

a) Electric plug out of the socket.

b) Bonded in different voltage.

c) Lack of electric power or fuse 

blown.

d) Make sure cold water switch in 

the rear side of dispenser is ON.

e) Voltage drop.

a) Plug in.

b) Connect in correct voltage.

c) Wait for electric power ON or 

change fuse.

d) Push the switches to the ON 

position.

e) Use a voltage stabilizer.

Water not cold 
from cold tank

a) Electric plug out of the socket.

b) After setup, it will take up to 1 

hour to chill the water until 
minimal set temperature.

c)  Make sure cold water switch in 

the rear side of dispenser is ON.

a) Plug in.

b) Wait one hour for the cold water 

supply.

c) Push the cold water switch 

(green) to the ON position.

Excessive 
heating around 
dispenser
body

a) The appliance very close to a wall.

b) Ventilation vents obstructed.

a) The appliance must be at least 25 

cm from the wall.

b) Clear the ventilation vents.

Noise

a) Product leaning on the wall.

b) Uneven placement.

a) The appliance must be at least 25 

cm from the wall.

b) Even the appliance.

Water leakage

a) A hole or a crack in the bottle.

b) Overflow in the water collector.

c) Drainage cap not well tightened.

a) Replace the water bottle.

b) Empty the water collector.

c) Tighten the cap.

Unpleasant 
taste of water

a) Cleaning is made with non 

recommended material.

b) Poor-quality water.

c) Water bottle shoddy.

a) Follow cleaning/sterilization 

procedure correctly.

b) Make sure that the mineral water 

supplier is of good quality.

c) Replace the water bottle.

Problem

Possible cause(s)

Solution

Steam coming 
out of 
dispenser

a) Excessive heating inside the 

hot water tank.

a) Disconnect the main power 

source and call service centre.

Water not hot
from hot tank

a) Electric plug out of the socket.

b) After setup, it will take up to 15-

20 min to heat the water until 
maximal set temperature.

c)  Make sure hot water switch in the 

rear side of dispenser is ON.

a) Plug in.

b) Wait 15-20 min. for the heat water 

supply.

c) Push the hot water switch (red) to 

the ON position.

13

14

Summary of Contents for ES11S

Page 1: ......

Page 2: ...s to be replaced replacement work shall be performed by authorised personnel only This product was developed for regions with an altitude of approximately 2000 meters For a higher region the water boiling point might be too low and cause product damages Thank you for choosing Frigidaire Our water dispensers are developed with high technical and quality standards with features to offer you even mor...

Page 3: ...educe risk of injury and property damage user must read this entire guide before assembling installing and operating dispenser Failure to execute the instructions in this manual can cause personal injury or property damage This product dispenses water at very high temperatures Failure to use properly can cause personal injury When operating this dispenser always exercise basic safety precautions i...

Page 4: ...hole 6 mm on the floor 3 Insert a screw anchor wall plug into the drilled hole 4 Move water dispenser Align fixing bracket hole with screw hole of the floor 5 Put the 25mm screw into the screw hole of fixing bracket 6 Tighten the screw Do not install the water dispenser in a location where there is a direct impact of sunlight or near heat sources as a stove oven etc Do not plug in the device unles...

Page 5: ... punch If the user prefers not to use the hole punch you can pull it off follow the next instructions 1 Remove the top cover with the hole punch 2 Turn clockwise the hole punch to fit it in tears 3 Remove the hole punch 4 Replace the lid on the water dispenser 5 Place the water bottle at the water cooler and make sure that it is well docked Never turn the appliance upside down or tilt it more than...

Page 6: ...t be turned on until 3 minutes later after turning off the power switch Do not operate or stop the appliance plugged in by the power cord or by pulling on the power cord Unplug the power cord by holding it by the plug In case cold or hot water is not needed for a long time turn off the respective power switch Food and fruits should not be placed on non refrigerated models to prevent putrefaction N...

Page 7: ...ng sterilization of the appliance 1 Disconnect the appliance from power source 2 Remove the water bottle and empty water reservoir through pressing the buttons until there is no water coming out 3 Open the drainage cap existing at the back of the dispenser and ensure that all the water flow out of the appliance 4 Prepare a chlorinated solution 2 litres of clean water and 0 5 tea spoon of bleach 5 ...

Page 8: ...se to a wall b Ventilation vents obstructed a The appliance must be at least 25 cm from the wall b Clear the ventilation vents Noise a Product leaning on the wall b Uneven placement a The appliance must be at least 25 cm from the wall b Even the appliance Water leakage a A hole or a crack in the bottle b Overflow in the water collector c Drainage cap not well tightened a Replace the water bottle b...

Page 9: ...W D H mm 220 240V 50 60Hz 570 W 450 W 120 W 2L H 4L H 10 38 C 90 11 92 kg 310 343 931 MODEL FS11W WITH CABINET Volt Freq Max power Heating power Cooling power Cold water Heat water Environmental temp Humidity Net weight Prod dimens W D H mm 220 240V 50 60Hz 570 W 450 W 120 W 2L H 4L H 10 38 C 90 11 08 kg 310 343 931 MODEL FS10W WITHOUT CABINET 15 16 ...