Cause A(most likely): sensor plug does not contact well with the power board
Remedy: check, clean or repair the plug and/or socket
Cause B: the wine compartment and its evaporator sensors are broken
Remedy: check the resistance value of the sensors and compare it to the value in the
diagram. If the actual resistance value is not in the prescribed range, repair the sensors.
4)
“
C3
”
displayed as the freezer temperature
Note:
Temperature sensed by the freezer sensor is beyond controllable range
Attention:
If such malfunction occurs, the appliance will keep on running. The refrigeration function
of the appliance is protected but temperature will not be displayed and Quick Freeze
function is disabled.
Check if the ambient temperature is above 45°C or not and if the appliance is just
switched on or not. If it is just switched on, check the temperature display after the
freezer has run for 1 hour.
Cause A(most likely): sensor plug does not contact well with the power board
Remedy: check, clean or repair the plug and/or socket
Cause B: the freezer sensor is broken
Remedy: check the resistance value of the sensors and compare it to the value in the
diagram. If the actual resistance value is not in the prescribed range, repair the sensors.
5)
“
C4
”
displayed as the freezer temperature
Note:
Temperature sensed by the freezer evaporator sensor is beyond controllable range
Attention:
If such malfunction occurs, the appliance will keep on running at the default temperature.
The refrigeration function of the appliance is protected but temperature will not be
displayed and Defrost function is disabled.
Check if the ambient temperature is above 45°C or not and if the appliance is just
switched on or not. If it is just switched on, check the temperature display after the
freezer has run for 1 hour.
Cause A(most likely): sensor plug does not contact well with the power board
Remedy: check, clean or repair the plug and/or socket
Cause B: the freezer evaporator sensor is broken