min.
12 mm
min.
2 mm
min.
38 mm
min.
2 mm
8.5
The installation of more than one appliance
Added parts:
connection bar(s), heat re-
sistant silicon, rubber shape, sealing
strap.
Only use special a heat - resistant
silicon.
580 mm
520 mm
490 mm
360 mm
+
-
=
20 mm
920 mm
The worktop cut out
Distance from the wall : minimum 50 mm
Depth : 490 mm
Width : sum widths of all the appliances
to be built-in and subtract 20 mm (see al-
so "Overview of all appliance widths" )
The installation of more than one appli-
ance
1.
Put down the dimension of the work-
top cut out and saw it out.
2.
Put the appliances one at time on
some soft surface, a blanket for ex-
ample, with the bottom side up.
3.
Put the seal stripe around the lower
edge of the appliance along the outer
edge of the glass ceramic.
4.
Loosely screw the fixing plates into
the appropriate holes in the protec-
tive casing.