SOI 12.06 FV
24/43
599 37 42-75
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
H
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the
resistance between the two terminals as described in the table below.
Table: Resistance of Motor
Motors
Resistance
Fan
motor
Approximately
293
Ω
Turntable
motor
Approximately
12.6
k
Ω
Convection
fan
motor
Approximately
220
Ω
Damper
motor
Approximately
11
k
Ω
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
I
NOISE FILTER TEST
CARRY OUT 3D CHECKS
Disconnect the leads from the
terminals of the noise filter.
Using an ohmmeter, check between
the terminals as described in the
following table.
MEASURING POINTS
INDICATION OF OHMMETER
Between N and L
Approx. 680 k
Ω
Between terminal N and WHITE
Short circuit
Between terminal L and RED
Short circuit
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS
J
BLOWN FUSE F1 20A
CARRY OUT 3D CHECKS
If the fuse F1 20A is blown, there is a short or a ground in electrical parts
or wire harness. Check them and replace the defective parts or repair the
wire harness.
CARRY OUT 4R CHECKS
CAUTION: Only replace fuse F1 20A with the correct value replacement.
H
BLOWN FUSE F2 F8A
CARRY OUT 3D CHECKS
1. If the fuse F2 F8A is blown when the door is opened, check the
monitored latch switch SW1 and monitor switch SW3.
2. If the fuse F2 F8A is blown by incorrect door switching replace the
defective switch(es) and the fuse F2 F8A.