3.9 Display PCB (level 2 – 3, segment LED display)
1. (-) button, level 2 (Not assembled on UltraActive)
2. (+) button, level 2 (Not assembled on UltraActive)
3. Segment
LED
4. Connector pressure switch PCB
5. Connector On/Off PCB
6. Connector Aeropro Active PCB, Level 3
7. Connector Power Module
8. Filter LED (Not assembled on UltraActive)
9. S-bag LED (Not assembled on UltraActive)
ATTENTION:
Boards and electronic devices could be
damaged by electrostatic discharges.
Don’t touch any components without any
ESD protection.