EN Publication
number
Nr
Rev. xx
Month/year
PR - 22/37
22
3 Levels of Electronic Control
3.1 Display Layout for level 1 model, slider control:
3.1.1 Basic software functionality
- ON/OFF
switch
-
Soft-start, function according to chapter “Softstart and motor power change”.
-
Automatic 50/60Hz detection.
-
Motor power regulated by slider.
3.1.2 Motor power regulation and LED-functionality
1.
Main plug connected:
- Motor shall be off.
3.1.3 Software calibration process of the slider potentiometer
Calibration process of the potentiometer, to calibrate min power position:
Erase the micro controllers actual calibrated value:
Disconnect the potentiometer from the control PCB.
Connect the main plug while keeping the On/Off button pressed.
Erase completed is indicated by oscillating the motor power.
Disconnect the main plug.
Calibrate potentiometer to microcontroller:
Make sure that the slider is adjusted to minimum power position.
Connect the main plug.
Calibrated value is now stored in the micro controllers memory and the cleaner can
be operated as normal.