14.4 Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Auxiliary
26 / 25
Semi-rapid
28 / 29
Rapid
38 / 35
Triple Crown
55
Oven
48
Grill
55
14.5 Gas burners for LPG G30 50 mbar
BURNER
NORMAL
POWER kW
GAS RATE g/h REDUCED POW‐
ER kW
INJECTOR
MARK 1/100
mm
Triple
Crown
4.0
290.8
1.6
94
Rapid
3.0
218.1
0.72
77
Semi-rapid
2.0
145.4
0.43
60
Auxiliary
1.0
72.7
0.35
43
Oven
3.9
283.6
1.5
87
Grill
2.5
181.8
1.6
68
14.6 Gas connection
WARNING!
Before you connect the gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the
fuse box. Close the primary
valve of the gas supply.
WARNING!
Use this appliance with the
LPG supply at a pressure of
50 mbar. If you supply the
appliance with a lower
pressure, the performance of
the appliance will be not
satisfactory.
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
www.electrolux.com