Installation instructions
Important – safety requirements
Where applicable Natural Gas and LPG
Gas versions of this appliance are
available.
Check that this model is suitable for
the type of supply available. This
appliance must be installed and/or
serviced by a competent person in
accordance with the Gas Safety
(Installation and Use) Regulations
Current Editions and the I.E.E. Wiring
Regulations.
Detailed recommendations are
contained in the following British
Standard Codes of Practice –
BS.6172, BS.5440: Part 2 and
B.S.6891. All British Standards must
be ‘Current Editions’.
This appliance must be installed by
a qualified electrician / competent
person (CORGI Registered). Safety
may be impaired if installation is
not carried out in accordance with
these instructions.
Before connecting the appliance
make sure that the voltage of your
electricity supply is the same as
that indicated on the rating plate.
This is situated on the front frame
of the appliance and can be seen
upon opening the door.
Alternatively the rating plate may
also be found on the back or top of
some models (where applicable).
Do not alter the electrical circuitry
of this appliance.
Provision for ventilation
This appliance is not connected to a
combustion products evacuation
device. It shall be installed and
connected in accordance with the
current installation regulations.
Particular attention shall be given to the
relevant requirements regarding
ventilation.
The room containing the appliance
should have an air supply in
accordance with BS.5440: Part 2
Current Edition. All rooms require an
openable window or equivalent and
some rooms will require a permanent
vent as well. For room volumes up to
5m3 an air vent of 100cm2 is required:
for room volumes between 5m3 and
10m3 an air vent of 50cm2 is required.
If the room has a door that opens
directly to the outside, no air vent is
required. For room volumes that
exceed 11m3 no air vent is required. If
there are other fuel burning appliances
in the same room, BS.5440: Part 2
Current Edition should be consulted to
determine the requisite air vent
requirements.
Prolonged intensive use of the
appliance may call for additional
ventilation, for example opening a
window, or more effective ventilation,
for example increasing the level of
mechanical ventilation where present.