Checking the main oven
1. Turn on the oven thermostat
control knob to mark 9 and
press the ignition button. As
soon as the burner is alight the
button can be released.
2. There should now be a low gas
rate to the burner, which is the
F.S.D bypass rate.
3. When the F.S.D. phial has
heated up it opens the F.S.D
valve which allows the main gas
supply to the oven burner.
4. After 1 minute check that the
flame covers the full width of the
burner and is stable.
5. Set the oven control to Mk 2,
close the oven door and check
that after about 10 minutes the
flame size has reduced.
6. Turn off the control and check
that the oven flames go out.
General note
Instruct the user on how to use the
appliance and its ignition system.