electrolux
16
Installation
Positioning
Remove all the packaging and install the
cooker in a dry, ventilated room not near
curtains, paper, alcohol, petrol etc.
The cooker should be placed only on
the floor, but not on the base.
This appliance is approved to class “1”
regarding overheating of surrounding
surfaces.
It is mandatory to keep 2 cm distance to the
adjacent furniture.
2 cm
2 cm
55 cm
69cm
2 cm
2 cm
55 cm
69
c
m
Ventilation
Gas combustion is possible due to the
oxygen in the air (2 m
3
air/h x kW installed
power – check the rating panel of the
cooker).
It is necessary to renew the air and that the
combustion products be discharged.
This appliance is not connected to a
combustion products evacuation device. It
shall be installed and connected in
accordance with current installation
regulations. Particular attention shall be
given to the relevant requirements regarding
ventilation.
The use of gas cooking appliance results in
the production of heat and moisture in the
room in which it is installed. Ensure that the
kitchen is well ventilated; keep natural
ventilation holes open or install a mechanical
ventilation device (mechanical extract hood).
Prolonged intensive use of the appliance
may call for additional ventilation, for
example opening of a window, for example
increasing the level of mechanical ventilation
where present.
Gas connection must be carried out
according to the rules in force.
The manufacturing company release the
unit, once tested, adjusted for the kind of
gas stated on the adjustment label located
on the back of the range, next to connection
pipe. Be sure that you are going to connect
the unit to the same kind of gas written on
the plate. Otherwise, follow all the
instructions of the paragraph “Ch a n g e o f
g a s ” .
For best efficiency and lowest consumption,
be sure that manifolds gas pressure
respects the values in the table of
“Sp e c i f i c a t i o n n o z z l e s ” .
G a s c o n n e c t i o n
Connection using a rigid pipe or a flexible
metal pipe
To ensure higher safety, it is recommended
to carry out the connection to the gas
system using rigid pipes (ex. copper) or
using flexible stainless steel pipes, to avoid
any stress to the unit.
Summary of Contents for EKG501102
Page 1: ...User Manual EKG501102 Cooker ...
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ...342 706 241 0A 032009 ...