background image

6

Instruction for the Installer

The following instructions about installation
and maintenance must be carried out by
qualified personnel in compliance with the
regulation in force.

The appliance must be electrically
disconnected before all interventions. If any
electric supply to the appliance is required to
carry out the work, ensure all the necessary
precautions are followed.

The side walls of the unit in which the hob is
going to be installed, must not exceed the
height of the working top.

Avoid installing the appliance in the proximity
of inflammable materials (e.g. curtains, tea
towels etc.).

Gas connection

It is indispensible that the connection to the gas mains
are carried out by means of an AGB tap. Choose fixed
connections or use a flexible pipe in AGB (stainless
steel).
If using flexible metallic pipes, be careful they do not
come in contact with mobile parts or they are not
squeezed. Use the same attention when the hob is
combinated with an oven.

IMPORTANT  - 

 To ensure a correct operation, a saving

of energy and the long-life of the appliance, the voltage
pressure of the appliance must correspond to the
recommended values.

Before fitting the appliance ensure that the installation
has the correct  voltage for the appliance. At full capacity,
the drop in pressure must not exceed 5%. Such a drop in
pressure is caused by the following parameters:
- maximum capacity of meter;
- diameter and lenght of the tube in front and behind the

meter;

A) Ramp with ending nut
B) Seal
C) Adjustable connection

Fig. 2

FO 2365

Gas Burner Rating

Ultra-Rapid Burner

4,0 kW

Class 3 Appliance
Setting

Liquid Gas G30/G31    28 - 30 mbar

Gas connection

G 1/2"

Electric Supply

220 / 240 V ~ 50 / 60 Hz

Hob recess dimensions

Length

270 mm.

Width

490 mm.

This appliance complies with the following
 Directives:

- 73/23

 - 

90/683

 (Low Voltage Directive);

- 89/336

 (Electromagnetical Compatibility Directive);

-

90/396

 (Gas Appliances)

- 93/68

 (General Directives)

and subsequent modifications.

Technical Data

- section of transit of variuos tubes positioned on the

circuit;

- diameter of eventual connections.

The adjustable connection is fixed to the comprehensive
ramp by means of a threaded nut G 1/2". All the
components shown in Fig. 2 have already been assembled
in the factory.
The appliance, before leaving the factory, has been tested
in order to give you the best results.

IMPORTANT

 - When the final connection has been

made, it is essential that a thorough leak test is carried
out on the hob and installation. Use some soapy water,

never a flame.

Summary of Contents for EHGT 318

Page 1: ...1 Gas Hob Mod EHGT 318 USER MANUAL 35692 3401 MY TH SG ...

Page 2: ...rovided in the interest of safety You MUST read them carefully before installing or using the appliance It is most important that this instruction book should be retained with the appliance for future reference Should the appliance be sold or transferred always ensure that the book is left with the appliance in order that the new owner can get to know the functions of the appliance and the relevan...

Page 3: ...as supply Lighting the burners For easier lighting proceed before putting a pan on the pan support 1 Pushtherelevantknobdownandturnitanti clockwise until it reaches the maximum position 2 After lighting the flame keep the knob pushed down forabout5seconds Thiswillallowthe thermocouple Fig 1 lett D to be heated and the safety device to be switchedoff otherwise the gas supply would be interrupted 3 ...

Page 4: ...e from the electrical supply before carrying out any cleaning or manteinance work This appliance cannot be cleaned with steam or with a steam cleaning machine Wash the enamelled components with warm soapy water Never use abrasive cleaners Frequently wash the caps and the crowns with hot soapy water carefully taking away any built up of food Carefully wash the stainless steel components with water ...

Page 5: ... done with the utmost care and attention For this reason we reccomend that for any problem you contact the dealer who sold it to you or our nearest authorized Service Centre specifying the nature of the problem and the particular model which you own Original spare parts certified by the manufacturer of the product and marked with the following sign can only be found at our approved Technical Assis...

Page 6: ...e recommendedvalues Before fitting the appliance ensure that the installation hasthecorrect voltagefortheappliance Atfullcapacity thedropinpressuremustnotexceed5 Suchadropin pressure is caused by the following parameters maximum capacity of meter diameterandlenghtofthetubeinfrontandbehindthe meter A Ramp with ending nut B Seal C Adjustableconnection Fig 2 FO 2365 GasBurnerRating Ultra RapidBurner ...

Page 7: ...the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules The connection cable has to be placed in order that in eachpart itcannotreachatemperature90 Chigherthan theroomtemperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the n...

Page 8: ...n compliance with the rules in force Adaptation to different types of gas Fig 6 FO 0392 Adjusting the minimum level To adjust the minimum level of the burners proceed as follows 1 Light the burner 2 Turn the knob on the minimum position 3 Removetheknob 4 With a thin screwdriver adjust the by pass screw see Fig 7 If changing from natural gas to LPG completely tighten clockwise the screw until a sma...

Page 9: ...m Hanging forniture units or hoods must be placed at 650 mm minimum from the hob Carry out the building in of the hob as follows 1 Put the relevant sealings supplied with the hob on the edges of the cut out taking care that the sealings meet without overlapping 2 placethehobinthecutout takingcareofitscentring 3 fix the hob with the relevant screws Fig 10 The traction of the screws is able to trace...

Page 10: ...tion is needed Kitchen unit with oven The hob recess dimensions must comply the indication given in Fig 9 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 12 and 13 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily...

Page 11: ...11 ...

Page 12: ...35692 3401 03 06 Grafiche MDM Forlì ...

Reviews: