Gas connection
•
Before installing the appliance, check that the location
provides the required clearances from combustible
materials and check if necessary to provide protection
to adjacent surfaces as required by the regulation. Make
provision for the gas supply to be connected to the
location.
•
Cut the opening in the bench top by the cardboard -
template given in the hob packing or to the dimensions
shown in Fig 7.
•
Remove the hob from the carton.
•
Install the hob in the cut-out (Fig 7)
•
Connect gas supply to inlet of hob. Turn the gas on and
check for leaks using soap solution and brush around
all the joints and connection.
•
Test the appliance; depress the control knob and turn to
full flame setting to activate the electric igniter. The
burner will ignite. Adjust control knob to the desired
setting. On initial usage you may have to repeat this
ignition function several times (to allow air to be purged
from the gas supply system). No adjustment should be
necessary. If any problem occur, refer to the servicing
instructions or the fault finding chart.
•
Ensure the manual is left with the user. If any of the
above procedures do not produce satisfactory results, the
agent service department should be consulted for more
specialized assistance.
USE ONLY LOW PRESSURE REGULATOR AND
UNADJUSTBALE PRESSURE MAX 30mbar FOR
THIS APPLIANCE
•
Flexible connection
•
The supply hose must be visible for its entire length (max.
one meter) and must be secured with a hose clamp X (Fig
8). The sealing washer must be fitted.
IMPORTANT SAFETY INSTRUCTION:
Upon completion of gas installation connections, it is
compulsory to check for gas leakage at the joint.
(Soap test)
Fig.7 (in mm)
Bench cut-out size viewed from front of bench, i.e. control panel at front.
If clearance between side/back walls and periphery of
the burner is less than 200mm, the walls must be
protected with non-combustible material. The protection
must extend a minimum distance of 450mm above the
burner. Horizontal surfaces less than 750mm vertically
above the hob must also be protected.
Soap test procedure
•
Turn the burner controls off and turn on the gas supply.
•
Apply soapy solution to each joint. (Figure 8)
•
Formation of bubbles indicates leakage and must be tightened.
•
Repeat soap test