12
Ignition HT Spark
Spark Generator
Ispra Control's BF 50046 - 240V 0.6 YA T 120
Spark Gap
Fixed
OVERALL DIMENSIONS
Width:
580 mm.
Depth:
510 mm.
Height:
88 mm.
Weight:
9,8 Kg.
Burner
Dia. Tap By-pass
Tap colour
1/100 mm
Auxiliary
28
Red/Red
Semi-rapid
32
Blue/Blue
Rapid
40
Black/Black
Aeration adjustment none
Instructions for the Installer
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
Thickness: 40 mm.
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
2.9
0.65
1.9
0.45
1.0
0.33
NOMINAL FLOW
RATE m
3
/h
0.276
0.062
0.181
0.043
0.095
0.031
NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
NOMINAL THERMAL
POWER kW
2.7
0.65
1.9
0.45
1.0
0.33
NOMINAL FLOW
RATE g/h
195
46.8
137
32.4
72
23.8
NOZZLE REFERENCE
86
40
71
32
50
28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Rear Left Burner (semi rapid)
Heat Input
1.9 kW (6483 BTU/HR)
Front Left Burner (rapid)
Heat Input 2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.
This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.
Engineer technical data
CLASS APPLIANCE: 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar
Rear Right Burner (semi rapid)
Heat Input
1.9 kW (6483 BTU/HR)
Front Right Burner (auxiliary)
Heat Input
1.0 kW (3412 BTU/HR)