background image

6

Gas Burners Rating

Rapid Burner (big)

2,8 kW (G30/G31)

2,9 kW (Town gas)

Auxiliary Burner (small)

1,0  kW

1,1 kW (Town gas)

Class  Appliance

3

Setting

Liquid Gas G30/G31  28-30 mbar

Gas connection

G 1/2"

Electric Supply

220 / 240 V ~ 50 / 60 Hz

Hob recess dimensions

Length

270 mm.

Width

490 mm.

This appliance complies with the following
Directives:

- 2006/95

 (Low Voltage Directive);

- 89/336

 (Electromagnetical Compatibility Directive);

-

90/396

 (Gas Appliances)

- 93/68

 (General Directives)

and subsequent modifications.

Technical Data

The following instructions about installation and
maintenance must be carried out by qualified
personnel in compliance with the regulation in
force.

The side walls of the unit in which the hob is
going to be installed, must not exceed the height
of the working top.

Avoid installing the appliance in the proximity of
inflammable materials (e.g. curtains, tea towels
etc.).

The appliance must be electrically disconnected
before all interventions. If any electric supply to
the appliance is required to carry out the work,
ensure all the necessary precautions are followed.

THE MANUFACTURER WILL NOT ACCEPT LIABILITY,
SHOULD ANY OF THE OTHER SAFETY INSTRUCTIONS
INCORPORATED IN THIS BOOK  OR THE REGULATION IN
FORCE BE IGNORED.

Instruction for the Installer

Summary of Contents for EHG 30210

Page 1: ...Gas Hob Mod EHG 30210 USER MANUAL 35692 3303 MY TH SG ...

Page 2: ...se warnings are provided in the interest of safety You MUST read them carefully before installing or using the appliance Important Safety Information Undernocircumstancesshouldyouattempttorepair the appliance yourself Repairs carried out by unexperienced persons may cause injury or serious malfunctioning Refer to your local Service Centre Always insist on genuine spare parts Ensure that all contro...

Page 3: ... putting a pan on the pan support 1 Pushtherelevantknobdownandturnitanti clockwise until it reaches the maximum position 2 After lighting the flame keep the knob pushed down forabout5seconds Thiswillallowthe thermocouple Fig 1 lett D to be heated and the safety device to be switchedoff otherwise the gas supply would be interrupted 3 Then check the flame is regular and adjust it as required Descrip...

Page 4: ...pans or pots with flat bottom Burner minimum maximum diameter diameter Rapid 180 mm 260 mm Auxiliary 80 mm 160 mm Fig 1 A B C CleaningandMaintenance Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Wash the enamelled components with warm soapy water Never use abrasive cleaners Frequently wash the caps and the crowns with hot soapy water caref...

Page 5: ... this reason we recommend that for any problem you contact the dealer who sold it to you or our nearest authorized Service Centre specifying the nature of the problem the appliance model Mod the product number Prod No and the serial number Ser No marked on the identification plate Service and original spare parts Original spareparts certified by the product manufacturer and carrying this symbol ar...

Page 6: ...tionsaboutinstallationand maintenance must be carried out by qualified personnel in compliance with the regulation in force The side walls of the unit in which the hob is going to be installed must not exceed the height of the working top Avoid installing the appliance in the proximity of inflammable materials e g curtains tea towels etc The appliance must be electrically disconnected before all i...

Page 7: ... according to the rules in force LPG use the rubber pipe holder D Fig 4 Always insert the gasket B Then proceed with the gas connection The flexible pipe should be made ready for use in such a way that nowhere it can reach overtemperature other than room temperature higher than 30 C if the flexible pipe to reach the cock must run behind the range it must be installed as shown in Fig 4 it is no lon...

Page 8: ...h between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules The connection cable has to be placed in order that in each part it cannot reach a temperature of 90 C The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the network pha...

Page 9: ...r must be fitted on the gas supply pipe in compliance with the rules in force Adaptation to different types of gas Fig 6 FO 0392 Adjusting the minimum level To adjust the minimum level of the burners proceed as follows 1 Light the burner 2 Turn the knob on the minimum position 3 Removetheknob 4 WhenconvertingfromLPGtotowngasunscrewabout one turn by pass pin until a regular small flame is reached 5...

Page 10: ...e a minimum distance of 100 mm Hanging forniture units or hoods must be placed at 650 mm minimum from the hob Carry out the building in of the hob as follows 1 Put the relevant sealings supplied with the hob on the edges of the cut out taking care that the sealings meet without overlapping 2 placethehobinthecutout takingcareofitscentring 3 fix the hob with the relevant screws Fig 10 The traction o...

Page 11: ...tion is needed Kitchen unit with oven The hob recess dimensions must comply the indication given in Fig 9 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 12 and 13 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily...

Page 12: ...t issued by the seller of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of residence for this particular model or range of appliances Theapplianceguaranteeispersonaltotheoriginalpurchaseroftheapplianceandcannotbetransferredtoanother user The appliance is installed and used in accordance with instructions issue...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...02 08 Grafiche MDM Forlì www electrolux com sg ...

Reviews: