11
90 cm Max.
70 cm Min.
B
D
E
C
*Gas
Cutout
5 cm
Opening
for access
door(s)
A
B
C
D
E
112 cm
112 cm
54 cm
22 cm
N/A
N/A
47 cm
46 cm
47 cm
N/A
N/A
N/A
N/A
N/A
N/A
92 cm
ca 10 cm
ca 10 cm
Grill
Distance to center of ignitor
button from side of gril
IGNIT OR PLATE
INSTALLATION
Side cutouts are needed on each side to feed
ignitor wires to the ignitor plates and allow
access to side gas connections .
(Size: 25 cm high x 12.5 cm long, set 1
back from front edge)
A
GFI Electrical outlet
for rotisserie motor
Built-in dimensions without using a Trim Kit
Built-in dimensions using a Trim Kit
Floor Support
area for grill
Note: Make sure to use a
non-combustible base and
sides for the structure
*A minimum 8 cm clearance is
required between the back of the
grill hood and a non-combustible
surface.
counter top
*Required Ignitor cutout
for front or side mount
44
Grill
Single
Access
Door
Dual
Access Door
A
B
C
D
E
112 cm
112 cm
53 cm
33 cm
N/A
N/A
47 cm
46 cm
47 cm
N/A
N/A
N/A
N/A
N/A
N/A
92 cm
44
Grill
Single
Access
Door
Dual
Access Door
Additional Requirements:
* Gas connection cut out in floor support needs to be 10 cm wide x 23 cm long, set 5 cm back
from front edge.
* Ignitor cutout is equal to a standard electrical outlet with a minimum depth of 6 cm.
* If using a backsplash apron or rear wall, locate electrical service on the left hand side for
rotisserie motor connection.
* A minimum clearance of 30 cm from the back must be maintained between the grill
and any combustible construction such as wood siding of a residence, 8 cm minimum
for non-combustible construction.
Built-In Instructions
for model EGL4401X