9.4
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown
4,0
1,4
146
Rapid
3,0
0,75
119
Semi-rapid
2,0
0,45
96
Auxiliary
1,0
0,33
70
9.5
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
1/100 mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
4,0
1,4
98
291
286
Rapid
3,0
0,75
88
218
214
Semi-rapid
2,0
0,45
71
145
143
Auxiliary
1,0
0,33
50
73
71
10.
ENERGY EFFICIENCY
10.1
Product information according to EU 66/2014
Model identification
EGG7253NOX
Type of hob
Built-in hob
Number of gas burners
5
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid
54.0%
Right rear - Rapid
52.0%
Centre middle - Triple Crown
52.0%
Left front - Semi-rapid
54.0%
Right front - Auxiliary
not applicable
Energy efficiency for the gas hob
(EE gas hob)
53.0%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of energy
- General
10.2
Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
www.electrolux.com