background image

7. 

INSTALLATION

WARNING!

Refer to "Safety information"
chapter.

WARNING!

The following instructions about
installation, connection and main-
tenance must be carried out by
qualified personnel in compliance
with standards and local regula-
tions in force.

7.1 

Important safety

requirements

This hob must be installed in accordance
with the Gas Safety (Installation and Use)
Regulations (Current Edition) and the IEE
Wiring Regulations (Current Edition).
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic
Gas Installation I.S. 813 Current Editions
and the ETCI Rules for Electrical Installa-
tions.

Provision for ventilation

Detailed recommendations are contained
in the following British Standards Codes
Of Practice: B.S. 6172/ B.S. 5440, Par. 2
and B.S. 6891 Current Editions.
The hob should not be installed in a bed
sitting room with a volume of less than 20
m³. If it is installed in a room of volume
less than 5 m³ an air vent of effective area
of 100 cm² is required. If it is installed in a
room of volume between 5 m³ and 10 m³
an air vent of effective area of 50 cm² is
required, while if the volume exceeds 11
m³ no air vent is required.
However, if the room has a door which
opens directly to the outside no air vent is
required even if the volume is between 5
m³ and 11 m³.
If there are other fuel burning appliances
in the same room, B.S. 5440 Part 2 Cur-
rent Edition, should be consulted to deter-
mine the requisite air vent requirements.
For appliances installed in the Republic of
Ireland please refer to the NSAI- Domestic
Gas Installation I.S. 813 Current Editions
Table Four.

Location

The hob may be located in a kitchen, a
kitchen/diner or bed sitting room (with a
volume greater than 20 m³), but not in a
bathroom or shower room.
The minimum distance combustible mate-
rial can be fitted above the hob in line with
the edges of the hob is 400 mm. If it is fit-
ted below 400 mm a space of 50 mm
must be allowed from the edges of the
hob.
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic
Gas Installation I.S 813 Current Edition
Section 7- Permitted Locations of Appli-
ance.

7.2 

Gas Connection

WARNING!

Any gas installation must be car-
ried out by a GAS SAFE REGIS-
TER installer.

Make sure that, once the hob is installed,
it is easily accessible for the engineer in
the event of a breakdown.
The manufacturer will not accept liability,
should the above instructions or any of
the other safety instructions incorporated
in this instruction booklet be ignored.
On the end of the shaft, which includes
the G 1/2" threaded elbow, adjustment is
fixed so that the washer is fitted between
the components as shown in the diagram.
Screw the parts together without using
excessive force.

A

B C

A)

End of shaft with nut

B)

Washer

C)

Elbow

Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.
steel or copper.

10 www.electrolux.com

Summary of Contents for EGG6343

Page 1: ...EGG6343 EN HOB USER MANUAL ...

Page 2: ...ou ll get great results every time Welcome to Electrolux Visit our website for Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www electrolux com productregistration Buy Accessories Consumables and Original spare parts for your appliance www electrolux com shop CUSTOMER CARE AND SERVICE We recommend the use of original spar...

Page 3: ... appliances and units Always be careful when you move the appliance because it is heavy Always wear safety gloves Seal the cut surfaces with a sealant to prevent moisture to cause swelling Protect the bottom of the appliance from steam and moisture Do not install the appliance adjacent to a door or under a window This pre vents hot cookware to fall from the ap pliance when the door or the window i...

Page 4: ...flammable vapours Keep flames or heated objects away from fats and oils when you cook with them The vapours that very hot oil releases can cause spontaneous combustion Used oil that can contain food rem nants can cause fire at a lower temper ature than oil used for the first time Do not put flammable products or items that are wet with flammable products in near or on the appliance Do not try to e...

Page 5: ...f injury or suffocation Contact your municipal authority for in formation on how to discard the appli ance correctly Disconnect the appliance from the mains supply Cut off the mains cable and discard it Flat the external gas pipes 2 PRODUCT DESCRIPTION 2 1 Cooking surface layout 3 4 5 1 2 1 Cooktop 2 Semi rapid burner 3 Triple Crown burner 4 Auxiliary burner 5 Control knobs 2 2 Control knobs Symbo...

Page 6: ... Do not keep the control knob pushed for more than 15 sec onds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute In the absence of electricity you can ignite the burner without elec trical device in this case approach the burner with a flame push the relevant knob down and turn it counter clockw...

Page 7: ...ewest scientific knowledge if you brown food specially the one which contains starch acrylamides can pose a health risk Thus we recommend that you cook at the lowest temperatures and do not brown food too much 5 CARE AND CLEANING WARNING Refer to Safety information chapter WARNING Deactivate the appliance and let it cool down before you clean it Disconnect the appliance from the electrical supply ...

Page 8: ...liance with a damp cloth and some detergent 3 At the end rub the appliance dry with a clean cloth 5 1 Cleaning of the spark plug This feature is obtained through a ceramic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed 5 2 Periodic maintenance Periodically speak your local Service Force ...

Page 9: ...echnician or dealer may not take place free of charge even during the warranty period These data are necessary to help you quickly and correctly These data are available on the supplied rating plate Model description Product number PNC Serial Number S N Use the original spare parts only They are available at Service Force Centre and ap proved spare parts shops 6 1 Labels supplied with the accessor...

Page 10: ...me room B S 5440 Part 2 Cur rent Edition should be consulted to deter mine the requisite air vent requirements For appliances installed in the Republic of Ireland please refer to the NSAI Domestic Gas Installation I S 813 Current Editions Table Four Location The hob may be located in a kitchen a kitchen diner or bed sitting room with a volume greater than 20 m but not in a bathroom or shower room ...

Page 11: ...r the new type of gas supply You can find this plate in the package supplied with the appliance If the supply gas pressure is changeable or different from the necessary pressure you must fit an applicable pressure ad juster on the gas supply pipe 7 4 Adjustment of minimum level To adjust the minimum level of the burn ers 1 Light the burner 2 Turn the knob on the minimum posi tion 3 Remove the knob...

Page 12: ...ance make sure the electrical supply voltage is the same as that indicated on the rating plate The rating plate is located on the bottom of the appliance The appliance is supplied with a 3 core flexible supply cord with a 3 amp plug If it is necessary to change the fuse use a 3 amp ASTA approved BS 1362 fuse A B C D E A Green and Yellow B 3 amp fuse C Brown D Cord clamp E Blue Should the plug need...

Page 13: ...0 mm min 100 mm 30 mm 10 mm 3 mm 11 mm 11 mm A A B A supplied seal B supplied brackets 7 8 Possibilities for insertion Kitchen unit with door The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The hob recess dime...

Page 14: ...s diameters Burner Ø By pass in 1 100 mm Auxiliary 28 Semi rapid 32 Triple Crown 56 Gas burners BURN ER NOR MAL POWER RE DUCED POW ER NORMAL POWER NATURAL GAS G20 2H 20 mbar LPG Butane Propane G30 G31 3 28 30 37 mbar kW kW inj 1 100 mm m h inj 1 100 mm G30 G31 g h g h Auxiliary 1 0 0 33 70 0 095 50 73 71 Semi rapid 2 0 0 45 96 0 190 71 145 143 Triple Crown 4 0 1 4 146 0 381 98 291 286 9 ENVIRONMEN...

Page 15: ...with the household waste Return the product to your local recycling facility or contact your municipal office ENGLISH 15 ...

Page 16: ...www electrolux com shop 356989701 A 122012 ...

Reviews: