Installation

Fig. 9

Unpacking

Check that the cooker hood is not damaged. Transportation
damages should immediately be reported to the transport
company. Damages, faults and eventually missing parts
should immediately be reported to the retailer. Dispose
carefully of the packaging material so that it is out of the
way of small children.

Position

The cooker hood should be mounted freely hanging on the
wall. The cooker hood must be at least 60 cm above electric
burners or electric range, or at least 70 cm above gas burners
or gas range. Fig. 9.

Electrical connection

The electric outlet should be placed inside the chimney.
The hood has a power cord and moulded plug with earth
connection for a wall outlet of 230V.

Mounting of hood on wall - Fig. 10

Fix the drilling template to the wall.

Make 3 Ø 8 mm holes in the wall.  2 at points H, 1 as
desired at points I.

Insert the three Ø  8 mm expansion plugs into the wall.

Insert 2 5x45 screws at points H but do not tighten them
completely.

Open the grid.

Fit the hood into holes H, tighten the 2 screws.

From inside the hood, insert the third 5x45 screw into
hole I.

Mounting under cupboard - Fig. 11

Make the holes on the bottom of the cupboard, using the
drilling template.

From inside the cupboard, insert the 4 supplied screws
and tighten them in the appropriate holes on the
appliance.

Extraction

Connect the air outlet to the smoke exhaust hose

Open the suction grid (Fig. 6).

Remove the carbon filters: remove by rotating both
filters anticlockwise (Fig. 7).

Check that the selection lever for extraction/
recirculation is in the position A. (Fig. 12).

Refit the suction grid.

Min

70 cm

Min

60 cm

Fig. 10

Fig. 11

Fig. 12

Selector

Extraction (A)

Recirculation (F)

1

2

3

4

1

2

3

4

195

63.5

36,5

119

85

=

=

Summary of Contents for EFT 800

Page 1: ...User Manual Istruzioni di montaggio e d uso EFT 800 UK I ...

Page 2: ...d or property The cooker hood must be at least 60 cm above electric burners or electric range or at least 70 cm above gas burners or gas range Ensure that the power cord does not get squeezed at the installation The cooker hood is only dead when the plug or the fuse is disconnected The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity Pl...

Page 3: ...ected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding the question of fumes discharge Extraction The appliance has two exhaust outlets A and B Fig 2 Important To use the back hole B remove the plastic cover Fig 3 pulling tabs E use a cutter or a sharp knife for a precise work in order to free the back hol...

Page 4: ...s the hood will expel air which is required by these other appliances Attend to it by opening a window The negative pressure in the room must not exceed 0 04 mbar to prevent fumes being drawn back into the room by the cooker hood Fig 5 Maintenance and cleaning Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning ...

Page 5: ...quid detergents Never use products containing abrasives Changing the light Disconnect the cooker hood from the main supply before changing the light Change the light by Fig 8 Remove the suction grid Fig 6 Replace the damaged part with one of equal rating If the hood does not function Before calling for service Check the plug is correctly connected to the wall socket Check the fuse Do not attempt a...

Page 6: ... Fig 10 Fix the drilling template to the wall Make 3 Ø 8 mm holes in the wall 2 at points H 1 as desired at points I Insert the three Ø 8 mm expansion plugs into the wall Insert 2 5x45 screws at points H but do not tighten them completely Open the grid Fit the hood into holes H tighten the 2 screws From inside the hood insert the third 5x45 screw into hole I Mounting under cupboard Fig 11 Make the...

Page 7: ... Fig 6 Check that the selection lever for extraction recirculation is in the position F recycle Fig 13 Check if carbon filter is already mounted and if not fit carbon filters Place a carbon filter as a cover of the inlet plastic grids that protects the fan motor then unlock it rotating clockwise until it stops Fig 14 ...

Page 8: ...15 ...

Page 9: ...LI1RSB ...