background image

31

Contents

Safety instructions .................................................... 31

Description of the cooker hood ................................ 32

Using the cooker hood .............................................. 33

Maintenance and cleaning ........................................ 33

If the hood does not function .................................... 34

Technical data ........................................................... 35

Installation ................................................................ 35

Guide to use the Instructions

The following symbols will be found in the text to

guide you throughout the Instructions:

Safety instructions.

Step by step instructions for an operation.

Environmental information.

 €

The cooker hood may only be used in a private household and for normal cooking purposes. It fulfils

international safety regulations and standards of quality. All precautionary measures however cannot fully

eliminate all the accident risks.

Therefore you should read through instructions, advises and safety instructions carefully before you install and

start using the cooker hood. Pay special attention to sentences with a warning triangle to avoid damages to

person or property. Save the instruction boook for future reference if the cooker hood is sold or left  to another

person.

Installation and service

•

Any electrical installation of the cooker hood must

be carried out by a qualified electrician and the

hood itself must be installed by someone with

experience. Installation made by an unqualified

person can lead to loss of function of the cooker

hood and possible damage to person and/or

property.

•

The cooker hood must be at least 40 cm above

electric burners or electric range. The cooker hood

is not approved for mounting above gas burners or

gas range.

•

Ensure that the power cord does not get 

 

squeezed

 

at

the installation.

•

The cooker hood is only currentless when the plug

or the fuse is disconnected.

•

Note that the exhaust air must not be conducted

through a flue which is used for fume extraction

from any other non-electrical appliances such as oil

burner or wood stove.

Use of cooker hood

•

Never leave any deep-frying, melting fat,

paraffin or any other inflammable unattended on

the hob. If event of fire: Immediately switch off

the cooker hood and the cooker. Note! Cover

the fire.  Never use water.

•

Never do any flambé cooking underneath the

cooker hood. It can cause a fire. Remember that

overheated fat may spontaneously ignite. Never

leave the fraying pan unattended.

•

It is essential that the grease filter is regularly

cleaned to avoid fat to drip on to the hot zone

and cause fire. Read also the part  “Maintenance

and Cleaning” in the instruction book.

Disposal

•

Prevent accidents when disposing your cooker

hood. Disconnect the power plug from the wall

socket and cut the power cord at the hood inlet.

Contact your local authority for information on

where to dispose the cooker hood.

Safety instructions

Summary of Contents for EFT 540

Page 1: ...821 27 91 01 1 Cooker Hood EFT 540 EFT 640 EFT 740 USER MANUAL ...

Page 2: ...epærer Livstiden for lavenergilysstofrør svarer til livstiden for 8 stk glødetrådspærer Energiansäästölamppu vastaa kestoiältään kahdeksaa 8 hehkulamppua Fabriken källsorterar Plåt wellpapp trä papper och cellplast Fabrikken kildesorterer sitt avfall Stål tre papir papp og plast Fabrikken sorterer affald Metal pap træ papir og plast Tehdas kierrättää Pellit pakkausmateriaalin puun paperin ja muovi...

Page 3: ...person can lead to loss of function of the cooker hood and possible damage to person and or property The cooker hood must be at least 40 cm above electric burners or electric range The cooker hood is not approved for mounting above gas burners or gas range Ensure that the power cord does not get squeezed at the installation The cooker hood is only currentless when the plug or the fuse is disconnec...

Page 4: ...ashers 4 pcs M5 mm nuts 4 pcs spacers 4 pcs 10 mm wall dowels 4 pcs locknuts 4 pcs plastic covers 2 pcs brackets Cold air valve Instruction book Following is ordered from retailer Venting kit When the cooker hood is to be connected to an evacuation channel use the venting kit containing one ventilation pipe one roof connecting metal flange and two clamps PNC 391 414 201 LONG LIFE carbon filter The...

Page 5: ... a higher speed than necessary The low speeds are adequate for ordinary requirements while cooking The high speeds should be used only if food has burnt while cooking or for other strong fumes Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning products Clean the filter regularly The grease that collects in the ...

Page 6: ...instructions The filter should be changed after about 3 years as its ability to absorb smells has reduced by then The filter insert is removed from the frame and is replaced with a new one according to the filter instructions Before calling for service Check the plug is correctly connected to the wall socket Check the fuse Do not attempt any repairs yourself that are likely to lead to further dama...

Page 7: ...hould immediately be reported to the transport company Damages faults and eventually missing parts should immediately be reported to the retailer Dispose carefully of the packaging material so that it is out of the way of small children Remove the transport supports C Fig 9 Position The cooker hood should be mounted freely hanging on the wall The cooker hood must be at least 40 cm above electric b...

Page 8: ... be drilled on the wall Drill in the markings with an Ø8 mm drill and fit rawl plugs into the holes Use the template printed on the packaging Fix the screws A Leave about 5 mm distance between the screws and the wall Hook the cooker hood on the screws A Remove the grease filter and mount the screws B in the two lower holes Remove the grease filter by pulling it backwards against the wall and then ...

Page 9: ...n place with a clamp Make sure the pipe is as straight as possible and does not hinder the movement of the valve flaps The pipe is connected to the mouth of the duct with the metal flange C which is included in the kit Fitting the carbon filter Only applicable for recirculation The LONG LIFE carbon filter special accessory for this hood is fitted instead of the grease filter The LONG LIFE carbon f...

Page 10: ... 1998 MO STF ...