43
WIRING REqUIREmENTS
The cooker mUST be installed in compliance with:
• Wiring connections in AS/NZS 3000 Wiring Rules
• Local regulations, municipal building codes and other
statutory regulations.
For new Zealand Only:
The cooking range must be connected to the
supply by a supply cord fitted with the appropriately
rated plug. This plug is to be compatible with the
socket-outlet fitted to the final sub-circuit in the
fixed wiring that is intended to supply this
cooking range.
Supply cord size required
EVE916BA, EFE916BA - 4mm
2
EFE956BA - 10mm
2
Data plate
gives information about rating
is located behind the bottom of
the oven door
Circuit
diagram
is located on the back panel of the
appliance
• A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000 -
Clause 4.7.1).
• Wiring MUST be protected against mechanical failure
(AS/NZS 3000 - Clause 3.9).
• The cooker requires a means of all pole disconnection
incorporated into the fixed wiring. This mUST have a
disconnection gap of 3mm.
• The cooker MUST be properly earthed.
NOTE: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
ImpOrTAnT!
Before you cook in your new oven it is important
that the protective oils used in the manufacture of
the product be removed.
• Make sure that the room is well ventilated (to allow
smoke to escape).
• Run the grill on high for 30 minutes without grill dish.
• Then run the oven on 220°C for 1 hour.
Connecting to services and commissioning
This appliance must be installed by an authorised person,
according to all codes and regulations of:
• Electrical supply authorities.
• Building regulations.
• Local government and council authorities.
• AS/NZS5601.1 (particular attention to 6.10.1 and figure
6.3, and clause 6.10.1.11).
• AS/NZS 3000 (particular attention to clause 4.3.11 and
clause 3.9).
Hard wiring detail
1. Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Securing points
Plastic clips
Plastic clip
Electrical connection location
- model EVE916BA
Entry point of electrical cable
99
113