background image

36

Safety warnings

for the installer

• When used as an extractor unit, the hood must

be fitted with a  150mm diameter hose.

• Should there already be a pipe of diameter 125

mm that ducts to the outside through the walls

or roof, it is possible to use the 150/125 mm

reduction flange provided. In this case the hood

will be slightly more noisy.

•

When  installing  the  hood,  make  sure  you

respect  the  following  minimum  distance

from the top edge of the cooking hob/ring

surfaces:

electric  cookers

500  mm

gas  cookers

650  mm

coal  and  oil  cookers

700 mm min.

• The national standard on fuel-burning systems

specifies a maximum depression of 0.04 bar in

such rooms.

• The air outlet must not be connected to chimney

flues or combustion gas ducts. The air outlet

must under no circumstances be connected to

ventilation ducts for rooms in which fuel-burning

appliances are installed.

• It is advisable to apply for authorization from the

relevant controlling authority when connecting

the outlet to an unused chimney flue or

combustion gas duct.

The air outlet installation must comply with the

regulations laid down by the relevant authorities.

• When the unit is used in its extractor version, a

sufficiently large ventilation hole must be

provided, with dimensions that are

approximately the same as the outlet hole.

• National and regional building regulations

impose a number of restrictions on using hoods

and fuel-burning appliances connected to a

chimney, such as coal or oil room-heaters and

gas fires, in the same room.

• Hoods can only be used safely with appliances

connected to a chimney if the room and/or flat

(air/environment combination) is ventilated from

outside using a suitable ventilation hole approxi-

mately 500-600 cm

 large to avoid the

possibility of a depression being created during

operation of the hood.

• If you have any doubts, contact the relevant

controlling authority or building inspector’s

office.

• Since the rule for rooms with fuel burning

appliances is “outlet hole of the same size as the

ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the perfor-

mance of the extractor hood.

• If the hood is used in its filtering function, it will

operate simply and safely in the above

conditions without the need for any of the

aforementioned measures.

• When the hood is used in its extractor function,

the following rules must be followed to obtain

optimal operation:

— short and straight outlet hose

— keep bends in outlet hose to a minimum

— never install the hoses with an acute angle,

they must always follow a gentle curve only

— keep the hose as large as possible

(preferably the same diameter as the outlet

hole).

• Failure to observe these basic instructions will

drastically reduce the performance and increase

the noise levels of the extractor hood.

for the user

• Always cover lighted elements, to prevent

excess heat from damaging the appliance.  In

the case of oil, gas and coal fired cookers it is

essential to avoid open flames.

• Also, when frying, keep the deep frying pan on

the cooker top/cooker under careful control.

• The hot oil in the frying pan might ignite due to

overheating.

• The risk of self-ignition increases when the oil

being used is dirty.

• It is extremely important to note that

overheating can cause a fire.

•

Never carry out any flambé cooking under

the  hood.

•

Always disconnect the unit from the power

supply before carrying out any work on the

hood, including replacing the light bulb

(take the cartridge fuse out of the fuse holder or

switch off the automatic circuit breaker).

•

It is very important to clean the hood and

replace  the  filter  at  the  recommended

intervals.  Failure  to  do  so  could  cause

grease  deposits  to  build  up,  resulting  in  a

fire hazard.

Summary of Contents for EFC 1410

Page 1: ...anweisung Notice d utilisation et d installation EFC 6940 EFC 1410 F I D Istruzioni per l uso User manual Installatie en gebruiksaanwijzing UK SM 8090 SM 8060 SM 8091 SM 8092 SM 8062 SM 8093 NL EFC 6940 EFC 1410 ...

Page 2: ...d Save the instruction manual and keep it available at use of the cooker hood Safety warnings 36 for the installer 36 for the user 36 Description of the appliance 37 Extractor version 37 Filter Version 37 Control Panel EFC 6940 38 Control Panel EFC 1410 39 Maintenance and care 40 Cleaning 40 Metal grease filter 40 Charcoal filter 41 Changing the light bulb 41 What to do if 42 Technical Specificati...

Page 3: ... of a depression being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the perfor mance of the extractor hood If the hood is used in its fi...

Page 4: ...re already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisier D Fig 1 Filter Version The air is filtered through a charcoal filter and returned to the kitchen through the top grill of the outlet pipe You will need an original ELECTROLUX KF20 charcoal filt...

Page 5: ...und indicates the reset Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen It is important to keep the kitchen windows closed and have a window in an adjacent room open depress towards the right to switch on the hood depress towards the left to switch on the light Fig 3 The control ball serves also as a light signal No signal The hood is swit...

Page 6: ... hood lamp on and off Light switch this switch is used to turn the light fitted in the hood on and off Extractor fan switch Push button 1 used to turn the fan off and to set the fan to speed 1 Push button 2 used to set the fan to speed 2 Push button 3 used to set the fan to speed 3 Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen It is impo...

Page 7: ...y four weeks Open the metal grease filter Pull out the spring lock to release the grease filter Fig 5 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when they are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing p...

Page 8: ...hree years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Remove the frame i which supports the filter h by turning 90 the two knobs g Fig 6 Insert the coal mattress inside the frame and put all parts back in their place To dismount proceed in reverse order Always specify the hood model code number and serial number when ordering rep...

Page 9: ...ood is not working Check that The fan speed is set high enough for the task The grease filters are clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The cooker hood has The safety cut out device has been tripped switched off ...

Page 10: ... and further information about Service Force please visit the website at www serviceforce co uk Please ensure that you have read the section What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty Please note that proof of purchase is required for in guarantee service calls Help us to help you Please determine y...

Page 11: ...ic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to anothe...

Page 12: ...d electrician Electrical connection for UK only Safety warnings for the electrician Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts The switch must be accessible at all times The following is valid in the United Kingdom only the wire which is coloured green and yellow must be connected to the terminal which is marked with the let...

Page 13: ...ly signed the lower side of the template corresponds to the lower side of the hood once mounted 2 Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws 3 Hang the hood 4 adjust its position 5 6 and from the inside of the hood sign one point for definitive fixing 7 remove the hood and drill an hole Ø 8mm 8 fit a wall plugs hang the hood again and fix it definitively with ...

Page 14: ...47 X X H X F F G G 16b 9 15b 15b 4 1 2 3 5 6 10 11 12 15a 5 6 13 5 6 7 8 16a 16a 16b 15a 14 14 F G H D 12 Ø 125mm Ø 120mm a b c A B 180 C OK Fig 9 Fig 10 Fig 11 EFC 1410 Fig 13 EFC 1410 Fig 12 ...

Page 15: ...ciali Mantelli in vetro Special accessories Vapour screen Extra leverbare accessoires Dampscherm SM 8090 A 90cm E Nr 942 120 654 SM 8060 A 60cm E Nr 942 120 700 SM 8091 E Nr 942 120 655 SM 8092 A 90cm E Nr 942 120 656 SM 8062 A 60cm E Nr 942 120 701 SM 8093 E Nr 942 120 657 A A ...

Page 16: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...

Reviews: