11 NO ACCESS TO DIAGNOSTICS PROGRAMME
11.1 No LEDs on the electronic board light
11.2 Some of the LEDs on the electronic board light
Replace or repair the power cable and perform
the diagnostics programme
Power cable and connection OK?
Replace the terminal block + suppressor and
perform the diagnostics programme.
Does the suppressor (incorporated in the main
terminal block) function correctly?
Replace or repair the wiring and perform the
diagnostics programme.
Remove the connector from the main terminal
block and connector J8 of the electronic board.
Measure the continuity of the wiring across
terminals
J8.1
and
L
. Is the circuit closed?
Measure the continuity of the
wiring across terminals
J8.2
and
N
.
Is the circuit closed?
Remove the connector from
the heater unit and measure
the closure of the thermostat.
Is the circuit across terminals 3
- 5 of the heater unit closed?
Identify the cause of the
interruption in the operation of
the fan causing the thermostat
to intervene, and eliminate the
cause. Replace the heater unit
and perform the diagnostics
cycle.
Replace/repair the knob or spindle
Does the programme selector function correctly
mechanically?
Replace/repair the wiring and
perform the diagnostics cycle.
Replace the electronic board and perform the
diagnostics cycle
Repair the mechanical problems
(control panel, pushbuttons, supports, spindle)
Do the pushbuttons move freely and correctly
action the various buttons?
Replace the electronic board and perform the
diagnostics cycle
It is not possible to access the diagnostics
system if the electronic board has not been
configured correctly: configuration errors (E93)
are indicated by the flashing of all the LEDs.