10 ALARMS
10.1 Displaying the alarms to the user
Operation of the alarms is configurable according to the model. Some or all of the alarms may be
displayed to the user.
Normally, all alarms except E44, E52, E63, E94, EB2 are displayed to the user.
When an alarm condition occurs, the drying cycle may be interrupted or paused; in some cases, for the sake
of safety, a forced cooling cycle is performed. In this case, the electronic board, if possible, disconnects the
power relay from the heater unit and powers the motor of the drum cooling fan. The cycle remains active
until the user switches off the appliance.
10.1.1 Alarm display during normal operation
The system displays the family of alarms to the user by a
repeated flashing sequence of the ANTI-CREASE/END OF
CYCLE LED (0.4 seconds on, 0.4 seconds off, with a 2.5 second
pause between sequences).
The buzzer emits a series of "bips" in synchronization with the
flashing of the LED
.
For example, in the case of alarm E53, the cycle would be interrupted and the ANTI-CREASE/END OF
CYCLE LED would flash repeatedly in the sequence shown in the table.
The five flashes indicate the
first
of the two numbers in the alarm code E
5
3 (the alarms relative to the same
function are grouped into families).
End of cycle
LED
Time (sec)
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
2.5
Value
1
2
3
4
5
Pause
Configuration errors (E93) are indicated by all the LEDs flashing.