A
2.
Use a minimum of 2 screws to attach
the appliance on the 2 sides (Detail A).
INSTALLING THE OVEN UNDER
A WORK SURFACE
Before the installation, connect the oven to
the electrical supply. Refer to "Electrical
connection".
A 592
N 560-568
A 567
N min. 550
A
A
115
20
ca.50
442
B
180
A 595
N 600
A = appliance
N = recess
WARNING!
Installation into flammable material
must agree with NIN SEV 1000
(Association of Cantonal Fire Insur-
ers) fire protection guidelines and
regulations.
CAUTION!
Make sure the cable is free when
you move the appliance.
1.
Push the cooker into the recess so
that it is flush with the surrounding
units.
A
B
min. 20
15
20
A
2.
Use at least 2 screws to fix the appli-
ance on both sides (Detail A).
WARNING!
When installing next to a wood-fu-
elled boiler, a heatproof and heat-
insulating plate must be mounted
at the height of the appliance and
at least 30 cm deep.
ELECTRICAL CONNECTION
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket supply
line. If there is no socket supply line, the
electrical installation must have an isolation
device which lets you disconnect the appli-
ance from the power supply. The isolation
device must have a contact opening width
of minimum 3 mm (in reference to NIN SEV
1000). The customer must have a socket
for the electrical connection that is accessi-
ble and outside the coordination room. The
length of the connection cable must be ap-
proximately 120 cm with lines connected
directly to the power supply.
28 www.electrolux.com