17
SERVICE
ERROR
CODE
REASON
UNIT REPSONSE
INDICATION DURING
FAILURE
CHECK WHEN FAILURE APPEARS.
i30
A leak or overflow
of water has been
detected in the
bottom pan.
Unit will stop and
drain pump will
continuously run.
1. Check for loose sump hoses or leaking within
sump area.
2. Check for overflow float is in the lower position
and freely moves.
3. Check for buildup of soils in sump.
i40
Pressure sensor failure Unit will shut off
displaying failure.
1. Check sensor wire harness and connection to
pcb.
2. Replace pressure sensor.
i50
A problem has been
detected with the
drain or wash motor.
Unit will shut off
displaying failure.
1. Check wash and drain motor wire harness and
connections to pcb.
2. Replace defective motor.
i60
A problem has been
detected with the
water heating system
The heating element
will be turned off
during the running of
any cycle.
1. Check heater connections and wire harness.
2. Check heater resistance.
3. Replace wash motor assembly which includes
heater.
i70
A problem has been
detected with the
thermistor within the
turbidity sensor.
The heating element
will be turned off
during the running of
any cycle.
Replace turbidity sensor.
i90
A problem has been
detected with the
software on UI and
powerboard.
UI is unresponsive
Replace both the UI and powerboard.
iB0
A problem has been
detected with Turbidity
sensor.
Turbidity not
operating properly.
1. Check turbidity connection and wire harness.
2. Replace turbidity sensor.
iC0
A problem has been
detected with the
electronic control
system.
Unit will stop
and retry to gain
communication to UI.
1. Check UI connection and wire harness.
2. Replace UI.
iD0
A problem has been
detected with the
wash motor.
Wash motor is not
operating at proper
speed.
1. Check connection and wire harness to wash
motor.
2. Replace wash motor.
iE0
Flow control
positioning
Heating element will
be switched OFF
1. FC type and anc installed
2. Check connection/wire harness.
iF0
A problem has been
detected the with
water fill level.
Cycle will pause
requiring user to
restart.
1. Check for buildup of soils in sump.
2. Replace pressure sensor.
Summary of Contents for E24ID74QPS
Page 1: ...Publication 5995668042 December 2015 Technical Service Manual DISHWASHERS ...
Page 2: ......
Page 18: ...18 5 1 Product Overview 5 Technical Details 5 2 Base Details Rear Side ...
Page 21: ...21 5 7 Hydraulic Circuit 5 8 Hydraulic Circuit Overview ...
Page 22: ...22 5 9 Sump Circulation Motor Variants Pump and Heater ...
Page 24: ...24 5 11 Omega Heater and Pump 5 12 Sump and Drain System Motor Variants ...
Page 29: ...29 5 18 Control Board for PB100 PB200 5 19 Control Board Replacement ...
Page 30: ...30 5 20 Example Wiring Diagram for PB100 5 21 Example Wiring Diagram for PB200 ...