4.4 Options
4.4.1 “1/2
load”
The 1/2 load option optimizes the washing cycle when only a small load is placed in the appliance.
When this button is pressed, certain parameters of the selected washing cycle are modified:
Exclusion of Pre-wash (if featured)
Reduction of the washing temperature
Reduction of the duration of the programme
OR
4.4.2 Delayed
start
This option enables the user to set a fixed start delay of the washing cycle.
to select the delayed-start time, with door open:
1. Switch the appliance on with
S0
button.
2. Press
the
S1
button to select the delayed-start time: LED
LD1
lights up to show that the selection has
been made.
The time reset when the relative button is pressed again: the LED
LD1
switches off.
3. Select the programme pushing
S2
button in sequence.
4. Close the door: the countdown starts.
5. When the countdown terminates, the selected cycle starts.
4.5 Cancelling a programme
To cancel a programme that has already started:
1. Press
button
S2
for at least 3 seconds.
2. The LED of the current programme flashes.
3. Salt/Rinse-aid LEDs light up (if featured): the programme is cancelled and the appliance returns to
preselection mode.
4. The End of cycle LED flashes.
5. Select the new programme.
4.6 Interruption of a programme (pause)
If the door is opened, the appliance remains on (the power loads are deactivated).
The Option LED remains on.
Closing the door the programme starts, after a brief delay, from the point at which it was interrupted.
Important! If the appliance is switched off or if the door is opened for more than 30 seconds during
the drying phase, the cycle is considered to have been terminated after the regeneration phase;
when the appliance is switched on again, it returns to programme selection mode.
4.7 Power
failure
The Power Failure function maintains the information relative to the cycle status even in the even of a
power outage; when the power supply is restored, the cycle resumes from the point at which it was
interrupted.
If the power failure occurs during the drying phase, the cycle is considered to have been terminated after the
regeneration phase.
The Power Failure has been defined in the following way:
When a Power Fail occurs, all loads switch off simultaneously to enable to save the data in EEPROM,
through the energy stored in the supply condenser of the control board, and when the power is restored, the
cycle restarts from the point at which it was interrupted.