DOC. NO. 5956.65J.00
P. 11 / 174
EFS - Dishwashing Systems Platform
Electrolux Professional
6 TEMPERATURE SETTING
In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and
tank
.
6.1
Factory Parameters
Sym.
Parameter Description
Unit
Min
Max
Factory
Default
Boiler Temperature: THRESHOLD.
When boiler temperature reaches this value, heaters switch off.
[°C]
45
95
78
Boiler Temperature HISTERESIS, (represent dead band).
Heater switch on if boiler temperature is below:
-
[°C]
2
10
2
Boiler Temperature: HIGH LIMIT.
When boiler temperature reaches this value
alarm appears.
Put 0 to disable
alarm.
[°C]
0
98
96
Boiler Temperature: LOW LIMIT.
During boiler warm-up, temperature must increase at least
°C
otherwise
warning appears.
Put 0 to disable
warning.
[°C]
0
10
1
Boiler Filling Timeout.
If filling time is longer than
,
alarm appears.
Put 0 to disable
alarm.
[min]
0
42
5
Boiler Temperature Adjust.
[°C]
0
7
4
Boiler Priority (enable boiler wait function)
0=disabled
1=enabled
-
0
1
1
Booster Function
Overheat gap over Boiler Temperature Threshold
[°C]
0
15
2
Boiler temperature negative differential: when the dishwasher is in
standby, boiler threshold becomes:
-
(Used to save energy during machine inactivity by keeping boiler
water at a lower temperature).
[°C]
0
20
0
Tub Temperature: THRESHOLD
When tank temperature reaches this value, heater switch off.
[°C]
40
85
63
Tub Temperature: HISTERESIS, (represent dead band).
Heater switch on if tank temperature is below:
-
[°C]
2
30
5
Tank Temperature: HIGH LIMIT.
When tank temperature reaches this value
alarm appears.
Put 0 to disable
alarm.
[°C]
0
95
75
Tank Temperature: LOW LIMIT.
During tank warm-up, temperature must increase at least
°C
otherwise
warning appears.
Put 0 to disable
warning.
[°C]
0
10
1
Tank Filling Timeout.
If filling time is longer than
,
alarm appears.
Put 0 to disable
alarm.
[min]
0
42
20