For the installer

• When used as an extractor unit, the hood must be fitted with a

150mm diameter hose.

• Should there already be a pipe of diameter 125 mm that ducts to

the outside through the walls or roof, it is possible to use the 150/

125 mm reduction flange provided. In this case the hood will be

slightly noisier.

•

When installing the hood, make sure you respect the following

minimum distance from the top edge of the cooking hob/ring

surfaces:

electric cookers

500 mm

gas cookers

650 mm

The hood can be installed above these heights but for optimum

performance it should be installed at the distance quoted for the

appropriate heat source.

• The national Standard on fuel-burning systems specifies a maximum

depression of 0.04 mbar in such rooms.

• The air outlet must not be connected to chimney flues or combus-

tion gas ducts. The air outlet must under no circumstances be

connected to ventilation ducts for rooms in which fuel-burning

appliances are installed.

• The air outlet installation must comply with the regulations laid down

by the relevant authorities.

• When the unit is used in its extractor version, a sufficiently large

ventilation hole must be provided, with dimensions that are approxi-

mately the same as the outlet hole.

• National and regional building regulations impose a number of

restrictions on using hoods and fuel-burning appliances connected

to a chimney, such as coal or oil room-heaters and gas fires, in the

same room.

• Hoods can only be used safely with appliances connected to a

chimney if the room and/or flat (air/environment combination) is

ventilated from outside using a suitable ventilation hole approxi-

mately 500-600 cm

 large to avoid the possibility of a depression

being created during operation of the hood.

• If you have any doubts, contact the relevant controlling authority or

building inspector’s office.

• Since the rule for rooms with fuel burning appliances is “outlet hole

of the same size as the ventilation hole”, a hole of 500-600 cm

2

,

which is to say a larger hole, could reduce the performance of the

extractor hood.

• If the hood is used in its filtering function, it will operate simply and

All manuals and user guides at all-guides.com

Summary of Contents for DD 8890

Page 1: ...haube Afzuigkap Hotte Cooker Hood Montage undGebrauchsanweisung Installatie engebruiksaanwijzing Notice d utilisation et d installation Operating and Installation Instructions All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...anel 57 58 Maintenance and care 59 Cleaning the hood 59 Metal grease filter 59 Charcoal filter 60 Changing the light bulb 61 What to do if 62 Technical assistance service 63 Special accessories 64 Technical Specifications 64 Mounting accessories included 64 Electrical connection 65 Wall unit mounting 66 All manuals and user guides at all guides com ...

Page 3: ...ung children or infirm persons without supervision Older children must be supervised if using the appliance Young children should be supervised to ensure that they do not play with the appliance WARNING Ensure that the appliance is switched off before replacing the lamp to avoid the possibility of electric shock This appliance is marked according to the European directive 2002 96 EC on Waste Elect...

Page 4: ...ation must comply with the regulations laid down by the relevant authorities When the unit is used in its extractor version a sufficiently large ventilation hole must be provided with dimensions that are approxi mately the same as the outlet hole National and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances connected to a chimney such as coal...

Page 5: ...and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a gentle curve keep the hose as large as possible preferably the same diameter as the outlet hole Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood All manuals and user guides at all...

Page 6: ...g ring Fig 1 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly noisier Filter Version The air is filtered through a charcoal filter and returned to t...

Page 7: ...ed runs for 5 minutes If the hood is on when the Intensive speed is activated the hood will revert to previous speed after 5 minutes If the hood is off when the Intensive speed is activated the hood will automatically turn off after 5 minutes To interrupt the Intensive speed press button 1 or 5 The letter P appears on the display and the remaining time the point a is flashing if interrupted an aco...

Page 8: ...r LED C illuminates the saturation indicator will be enabled To disable it Press buttons 4 and 5 again simultaneously and hold them for 3 seconds until the charcoal filter LED C goes out Grease filter LED F LED F will start to flash when it is time to clean the grease filter Cleaning will be necessary after 40 working hours Always comply with the maintenance instructions for the grease filter Char...

Page 9: ...it must always be used either in the external extraction or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Removing the metal grease filter First push the metal grease filter stop backwards then extract the filter pulling downwards Fig 3 Hand washing Soak grease filters for about one hour in hot water w...

Page 10: ... parts gets stuck on the filter and later causes bad odours To reactivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Fitting Remove the frame i which supports the filter h by turning 90 the two knobs g Inser...

Page 11: ... inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the cooker hood from the main supply Remove the lamp cover use a screw driver as a lever Fig 5 Replace the old bulb with a new one of the same type Refit the lamp cover If the light does not come on make sure the bulb has been inserted correctly before contacting your local Service ...

Page 12: ...and outlets are not blocked The cooker hood has The safety cut out device has been switched off during operation tripped Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Servi...

Page 13: ... telephoning When you contact us we need to know Your name Clearandconcisedetailsofthefault Address and post code Name and model of the appliance Telephone number E number Serial number This information can be found on the rating plate which can be seen when the grease filtersareremoved If you require Customer Service in the Republic of Ireland please contact us at the address below AEG Electrolux...

Page 14: ...Lengthof the cable 150 cm 150 cm Electrical connection 220 240 V 220 240 V Mounting accessories included 1 chimney support 1 reduction flange Ø 125 120 mm 1 deflector 1 allen spanner for TORX screws 1 support bracket 6 wood screws 5 x 45 mm for wall mounting 6 wall plugs Ø 8 mm for wall mounting 2 metal screws 2 9 x 6 5 for chimney flue mounting DD 8890 HD 8890 only 4 metal screws 3 5 x 9 5 to aff...

Page 15: ... appliance must only be carried out by an authorised electrician Electrical connection for UK only Safety warnings for the electrician Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts The switch must be accessible at all times The following is valid in the United Kingdom only the wire which is coloured green and yellow must be con...

Page 16: ...nd adjust its position 5 6 From the inside of the hood mark two points for fixing 7 Remove the hood 8 and drill two holes Ø 8mm 9 fit two wall plugs 10 Drill two holes Ø 8mm on the upper side close to the ceilling fit two wall plugs 11 In case the hood is to be used in filter version mount the deflector F on the chimney support with four screws 2 9x6 5 Two screws for model DD 8820 HD 8820 and fix ...

Page 17: ...67 Fig 7 17b 17b 4 13 4 13 1 2 3 11 11 12 15 17a 17a 65 16 B G H 8 8 18 F 9 10 14 7 9 10 14 7 5 6 F G 19 19 DD 8820 HD 8820 All manuals and user guides at all guides com ...

Page 18: ... of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world AEGElectrolux Addington Way Luton Bedfordshire LU4 9QQ http www aeg co uk All manuals and user guides at...

Reviews: