6-15/16"(
∅
176)
44"(1117)
29-9/16"(750.4)
4-
∅
1/4"(4-
∅
6)
4-
∅
9/16"
(4-
∅
14.5)
8-1/4"
(210)
9-5/16"
(236)
2-3/16"
(56.1)
43" (1091.6)
1/16" (1.5)
10-13/16" (275) 6-1/8" (155)
31-11/16" (806.4)
14-13/16"
(376.8)
1-1/16"
(26.3)
2-3/16" (55.6)
17-1/2"(453.6)
11-3/4"(298)
45" (1143)
30" (762)
12-5/16"(314)
17-1/2"(453.6)
16-3/4"(425.2)
10-7/16"
(265.4)
∅
7/8"(
∅
22.6)
5/8"(15)
14"(355.6)
3-1/8"(80)
Roof cap
Duct
(For vertical discharge)
Range hood
Wood hood
Soffit
Note:
2
×
7" or 1
×
10"~12"
round duct
Fan Switch
(Right)
Fan Switch
(Left)
Front Cover
Enclosure
Filter
Lamp Switch
Lamp Switch
High Switch
Medium Switch
Low Switch
OFF Switch
Pilot Lamp
Lamp (Not supplied)
(PAR20 bulb,
in the base diameter
26mm: medium base)
INSTALLATION MANUAL
Model: BUF-08P
1U03 2781
Before installation and operation, read these instructions carefully
and use this product only in the manner described by the
manufacturer in the operation manual.
The instruction shown below are used to alert you to potential
personal injury and property damage hazards.
There are three hazard classifications based on potentially
dangerous situations.
Obey all safety instructions that show these symbols to avoid
possible injury, death and property damage.
SAFETY INSTRUCTIONS
WARNING:
WARNING indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION:
CAUTION indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
NOTE
: The safety instructions are explained with the following
pictographic symbols.
means forcible execution. It indicates actions, if
any, that must be done.
WARNING
1. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b) Before servicing or cleaning the unit, switch power
off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION
INSTALLATION
1. Preparation
2. Range Hood Mounting
3. Connecting Power Supply Wires
1
Remove the nut from the conduit
connector at the end of power wiring.
2
Remove one screw fixing the
wire cover then slide it to detach.
4. Final Assembly and Check
Range Hood
3. Read specification label on this product for further
information and requirements.
2. To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls, ceilings or into attics,
crawl spaces or garages.
6. Fasten the filter and other parts securely. Incorrect
attachment may result in personal injury or
property damage.
4. Use only for the purpose of kitchen ventilation.
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
5. Do not install this range hood in the bathroom or
in other wet rooms since electrical shock and
damage may result.
2. To reduce the risk of fire or electric shock, do not
use this product with any solid-state speed control
device.
b) Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guidelines and safety standards such as those
published by the National Fire Protection
Association (NFPA), and The American Society
for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
c) When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
d) Ducted fan must always be vented to outdoors.
1
This range hood is designed
to discharge upward. For
vertical discharge, run duct
works between the hood
location and roof cap location.
To get the best result, use a
minimum number of
transitions and elbows.
Be sure to attach a roof cap
to avoid rain from entering
the exhaust duct.
2
The range hood unit
must be mounted to
a liner which has
the following
dimensions. Install
the liner securely
after checking that
the opening size of
the liner is the same
as the figure right.
• Ensure that the metal duct does not touch other metal housing materials,
otherwise fire or electric shock could result.
• When the liner is installed in the wooden hood, the inside of the wooden
hood placed above the cooking surface must be fully covered by the liner
including bottom edges. Select a suitable liner according to the size and
shape of the wooden hood and install properly.
• The liner should be installed tightly. If the liner installation is not correct,
the range hood unit may become detached and fall.
• Wear working gloves to avoid injury.
CAUTION:
5. Explanation to the End User
(1) Referring to the Operation Manual, explain the operation of this range
hood to end users.
(2) The Installation Manual and Operation Manual should be given to the
end user.
2
Check
(1) Turn on the electrical circuit to the range hood.
(2) Make sure that the switches and light operate correctly.
Refer to page 4 of the Operation Manual.
(3) Make sure that the range hood functions properly and it has
no abnormal noises and/or vibration.
• Electrical wiring should be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated construction.
An unqualified person doing the work could result in fire, electric shock
or injury.
• This range hood uses 120V AC. Do not connect to other voltage since
fire, electric shock or damage could result.
Be sure to switch power OFF
at service panel before wiring.
3
Connect the conduit through
the connecting hole of the
enclosure using the nut
previously removed.
4
Connect wires tightly and securely
using wire connectors (not supplied).
Connect the electrical wires as follows:
5
Replace the wire cover with
sliding it as shown and using
the screw removed previously.
Make sure that all wires are
connected properly and
enclosed inside of the wiring
compartment.
5
Align 4 screw holes of the liner and range hood, then fix securely
using the supplied screws (M5
×
30) and nuts.
Note:
Fasten all the screws and nuts evenly.
CAUTION:
CAUTION used without the safety
alert symbol indicates a potentially
hazardous situation which, if not
avoided, may result in property
damage.
means prohibition. It indicates actions, if any, that
mustn’t be done.
4. TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
5. This unit must be grounded.
CIRCUIT DIAGRAM
6. Install this range hood to a liner. Check that the
hood is correctly installed, since incorrect
installation could result in the range hood
becoming detached and falling off.
7. Connect only to an AC120 Volt power source or
the range hood could result in fire, electric shock,
and damage.
DIMENSIONS
CAUTION:
WARNING:
WARNING:
Unit: inch (mm)
NAMES OF PARTS
RANGE HOOD LOCATION
1
The range hood must be installed just
above the cooktop.
2
The minimum distance from the
cooking surface to the bottom of the
range hood must be 24".
3
The total weight of the BUF-08P
range hood unit is 70.4 lbs. (32 kg)
4
Power requirements are:
AC120 V, 60 Hz, 5.8 Amp
• Check that the hood is correctly installed, since incorrect installation
could result in the detachment of the range hood and the unit could fall.
• To protect hands from injury, wear working gloves when installing the
range hood.
CAUTION:
ACCESSORIES
Screw M5
×
30
Four (4) pieces
Nut with plate
Four (4) pieces
Mounting bracket
One (1) piece
24" (Minimum)
Cook top
Liner
FWD switches & lamps side
44" (1117)
16-7/8" (428.9)
43-3/16" (1096.3)
8-1/4" (210)
4-
∅
1/4" (4-
∅
6.5)
Front cover
Exhaust
port
Filter
Loosen 2 screws
to remove the filter.
Conduit
(Not supplied)
Nut
(Not supplied)
Wire cover
Hook
Lamp Switch
Fan Switch
Push to
turn ON
Turn the switch
clockwise
120V
60Hz
Connector
Connector
Connector
Connector
Connector
Connector
Connector
Connector
Motor
Motor
Red
Red
Or
ange
Or
ange
White
White
White
White
White
White
White
Blac
k
Blue
Blue
Bro
wn
Red
Or
ange
White
Blue
Bro
wn
Red
Or
ange
White
Blac
k
Blue
Bro
w
n
Red
Or
ange
White
Blue
Bro
wn
Bro
wn
Or
ange
Blue
Bro
wn
Black
White
Black
Black
Blac
k
Black
Black
Black
Black
Black
White
Black
Black
White
Green
Black
Black
Grey
Grey
Grey
Grey
Black
Black
Yellow
Yellow
Yellow
Black
Black
Pilot Lamp
Pilot Lamp
Lamp:50W
Lamp:50W
Lamp:50W
Fan Switch
Fan Switch
Capacitor
Lamp Switch
Purple
Purple
Purple
Washer
*
Bracket
*
Not supplied
Spring-washer
*
Nut
*
Mounting bracket
Beam
3
Put 4 all thread rod (
∅
12~14 anchor bolt, not supplied) into the corner
holes of the mounting bracket, and secure them using washers, spring
washers, and nuts. Place the mounting bracket on the beam of the
ceiling as shown.
3. TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
a) Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction.
• Black to Black
• White to White
• Green to Green
WARNING:
In this manual, the following method is explained as a standard
installation.
There may be some different cases depending on the structure of
the ceiling where the mounting bracket is placed or the shape and
mounting condition of the wood hood.
In such a case, please arrange to find best possible way according
to the condition of the place where the range hood is installed.
Detach
the tape.
Tape
Clamper
Keyhole
Clamper
Fan unit
Keyhole
FWD
Remove first
Remove second
6
Using washers, spring washers, and double nuts, attach the range
hood to all 4 threaded rods securely.
4
Hold up the range hood,
and with inserting the
exhaust port into the duct,
pass all 4 threaded rods
through the corner holes of
the range hood.
Note:
Do not touch the switch
buttons when holding the
unit as damage may result.
Note:
The mounting bracket should be securely fastened at this point
to simplify installing the range hood later.
1
Place the range hood
as shown and detach
the left and right filters
by loosening 2 screws.
Then remove 4 screws
fixing the front cover
and detach the front
cover.
Note:
Pay attention not
to deform the
exhaust ports.
Liner Dimensions
Unit: inch (mm)
Note:
If taping from the outside is impossible, remove the exhaust port
and insert the duct end to the range hood directly, then make
inside taping on the duct end. Be sure to attach a duct cover with
damper in this case.
Duct
Non-flammable
tape
Range hood
Duct
Exhaust port
Washer
*
Washer
*
Enclosure
Use less than
∅
1"
washer to avoid
overlapping with
the enclosure bend.
Spring-
washer
*
Nut
*
*
Not supplied
∅
1"(
∅
25.4)
7. Keep your hands and other objects away from
the fan while it is in motion. The range hood may
injure you or damage itself.
3
Turn over the range hood and detach
the tape on the exhaust ports.
Note:
Do not remove the keyhole screws.
(3) Remove screws attaching to the top plate.
(4) Disconnect wiring connector coming from the fan unit.
(5) Slide the fan unit rightward to disengage from fixing hook,
then pull it up while avoiding keyhole’s screws to remove from
the range hood.
FWD
Connector
Slide
Slide
Remove this side unit
Hook
Screw
Screw
Connector
Push with a
screwdriver etc,
and pull off.
Liner
Liner
[Securing plate
turns while
passing through
the opening
of Liner]
Securing plate
Nut with plate
[Right & left, each two (2) places]
Nut with plate
Four screws
(M5
×
30)
Slide
Slide
Hook
Screw
Attach this side unit
Bracket
Fan unit
Wire
Keyhole
FWD
(6) Three 50 Watt halogen light bulbs (not supplied)
can be mounted in this range hood.
1
Assembly
(1) Attach the fan units respectively by sliding
them leftward to engage with bracket hooks
and keyholes, then tighten screws.
Note:
Pass through the wiring over the bracket.
(5) Attach the front cover, and secure
it with 4 screws.
Then attach the filters.
Prior to function check, install
light bulbs (PAR20 bulb, with
base diameter 26 mm: medium
base), rated at 120 V - 50 Watt
or below.
Front cover
Screw
Filter
Bulb
(Not supplied)
2
Remove the fan units.
<Attention>
7
Make the duct joints secure and air-tight using non-flammable tape
such as duct tape, etc. (Not supplied)
Non-flammable tape
(2) Fix each fan unit using the
removed screws.
(3) Connect each fan unit’s
wiring connector.
Note:
Be sure to connect
firmly as illustrated.
(4) Fasten each fan unit’s
wiring clamper.
Connector
Clamper
FWD
Connector
Clamper
Note:
During installation, be careful not to
touch the fan switches. If two or more
switches are pushed at once, it may
be a cause of failure.
(1) Release each fan unit’s
wiring clamper.
(2) Remove total 4 screws
from each unit.
Fan unit
Fan unit
Remove this unit first
FWD
Fan unit
Fan unit
Attach this unit first
FWD
Check that the fan unit is hanged securely on
the keyhole screw and fixing hooks when
attaching. It may be a cause of injury if dropped.
CAUTION:
The following light bulbs are recommended for this range hood.
• GE Model No. 50PAR20H/FL25
• SYLVANIA Model No. 50PAR20/HAL/DL/NFL
Turn the lamps clock-wise to install.