13
2 - Setting for recirculation:
a) Apply the reducing spigot
“7B”
to the upper part of the extraction unit
“7D”
.
b) Fit the recycling spigot
“7A”
to the reducing spigot
“7B”
, directing it in the position
chosen for air evacuation.
c) Fit the charcoal filter inside the canopy (see paragr. 3.2 - part two) after power
connections have been done (paragr. 4.7).
4.4 - Electrical connection
a) Always carefully follow all instructions in paragr. 3 concerning safety.
b) Connection to mains supply must be done by passing the power cable through the
centre hole of the frame.
c) Connect the mains cable to the mains supply.
4.5 - Fitting the chimney
a) Insert the upper pipe
“S” (4B)
of the telescopic chimney and secure with the two
screws
“3A”
.
b) Insert the lower pipe
“I” (4C)
of the telescopic chimney, positioning it so that
opening
“4D”
, in the event of evacuation fitting, is aligned with the recircualtion
spigot
“7A”
. Note: Do not fit the small directional grille “G”. This operation must be
done after installation of the canopy “C”. Support pipe
“4C”
with one hand to allow
subsequent fitting of the canopy item.
4.6 - Fitting the canopy
a) Remove the three grease filters
“8D”
by applying pressure to the handles
“8E”
.
b) If fitted, remove the two charcoal filters
“8C”
.
c) Position the canopy item
“8A”
in line with the holes of lower frame
“I”
and secure
with 4 screws
“8B”
. Note: No further operation must be carried out without having
tightened the 4 screws “8C”. During this operation, until at least one screw “8C”
has been tightened, slightly support the canopy item to avoid accidental
movement.
d) Fit the directional grille
“4E”
in slot
“4D”
.
4.7 - Electrical connections
a) Remove cover
“9B”
by removing screw
“9A”
.
b) Remove connector
“9D”
and connect it to
“9E”
from the motor assembly.
c) Refit the cover
“9B”
paying attention that the connector cable is correctly
positioned in slot
“9C”
.
d) Once all the connections have been done, check correct operation of:
-
LIGHTS
-
MOTOR START
-
SPEED CHANGE
Part 1 - INSTALLATION INSTRUCTIONS