background image

Model code: DD520BK

Instruction manual for downdraft hood

Contact Caple on 0844 800 3830 or for spare parts www.4caple.co.uk

Summary of Contents for DD520BK

Page 1: ...Model code DD520BK Instruction manual for downdraft hood Contact Caple on 0844 800 3830 or for spare parts www 4caple co uk ...

Page 2: ...tly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste han dling of this product For more detailed information about recy cling of this product please contact your local city office your household waste disposal service or the shop where you pur chased the product This appliance is marked according to th...

Page 3: ...scription of the applianc 5 2 INSTALLING THE HOOD Mounting the hood 6 Removal of the filter cartridge 7 Mounting the filter cartridge 7 Electrical hook up of the hood 8 3 HOW THE HOOD WORKS 9 4 CLEANING THE HOOD 11 5 OPERATIONAL ANOMALIES 12 6 AFTER SALES SERVICE 12 3 ...

Page 4: ...rom non electrical sources so that the hood does not ventilate these combustion fumes It is prohibited to cook food over open flames or operate gas hobs without pots or pans on them under the hood itself the flames sucked into the hood might damage the appliance Deep frying under the appliance must be done under constant supervision as hot oils and fats may ignite Respect the guidelines for cleani...

Page 5: ...5 1 TO THE ATTENTION OF THE USER EN DESCRIPTION OF THE APPLIANCE ...

Page 6: ...tallation and connecting the appliance to the mains electricity lift the down draft and remove the door block Fig 5 6 7 Then open the door Fig 8 9 remove the PVC grease filter shield Fig 10 then place the filters as illustrated in Fig 11 8 In the version of the Downdraft equipped with motor install the motor group adjusting the air evacu ation direction as required either downwards or upwards Afte...

Page 7: ...stallation must conform to the regulations in force regarding the ventilation of en closed environments In particular discharged air must not be channelled into a conduit used for exhaust discharge or discharge from devices that operate with gas or other com bustible materials The use of unused conduits is not permissible without the approval of a qualified technician The product can be installed ...

Page 8: ...ect ground connection The fuse used must be 10 or 16 A If the power cable is damaged call the after sales service to avoid any risk Attention If the hood presents some form of anomaly unplug the appliance or remove the fuse corre sponding to the appliance s power line If the appliance has no plug or if the plug is not easily accessible then a device needs to be fit ted to cut it off from the mains...

Page 9: ...ion panel 10 minutes after it has been enabled Model SDD3 TOUCH CONTROL VERSION Fig 15 OFF switch Fig 15 It is used to close the aspiration panel completely or to position it at inter mediate heights at least mm 180 above the cooktop While closing the aspiration panel keeps on working at the speed set up to the height of mm 180 from the cooktop Below this height the aspiration function is automati...

Page 10: ...rs of continuous operation from the last setting the appliance turns off and closes automatically When the front panel is removed for cleaning and maintenance operations all the electronic aspiration and movement functions are locked Anti pinching safety device if anything is obstructing the closure operation of the down draft the operation will stop and the downdraft will move up again ...

Page 11: ...dry with a soft cloth Grease filter After 30 hours operation the button pad will sig nal that the grease filter is saturated by flashing the 4 speed LEDs Press the timer button to reset The grease filters can be washed by hand or in the dishwasher These filters need to be cleaned on a reg ular basis because otherwise they may present a fire risk Refit the grease filters and front panel making sure...

Page 12: ... carbon filter is not worn hood n recirculation mode The hood stops in the middle of ope ration Check that there is not a power outage the omnipolar device has not tripped Any maintenance on your equipment should be undertaken by either your dealer or another qualified mechanic who is an authorized agent for the brand appliances When making an appointment state the full reference of your equipment...

Page 13: ...13 1 2 3 4 6 5 ...

Page 14: ...14 7 8 9 10 11 Pusch ...

Page 15: ...15 12 13 14 14 bis 15 ...

Page 16: ...16 16 17 18 19 20 21 ...

Page 17: ...17 22 A B C D E F ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...9 2 2 422 M 2 12 ...

Reviews: