38
TECHNICAL DETAILS
DIMENSIONS
Height:
900 mm (nominal)
Width:
600 mm (nominal)
Depth:
600 mm (to front of door panel)
Weight: 60Kg
Net
Space for fixing at hotplate level 2mm minimum clearance.
Space for fixing above hotplate level See important note 'Location of Appliance'.
Minimum space above hotplate 650mm (If cooker hood is fitted refer to the cooker hood installations.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas connection:-
Rear left hand side of appliance at hotplate level Rc ½ (½" B.S.P. female)
Electrical connection:-
230 - 240 V 50 Hz Mains connected at rear centre of appliance using at least
6mm
2
multi core PVC insulated cable.
LOADING INFO: Electric ovens
Voltage:
230-240 Volts AC 50Hz
Wattage:
4.4 - 4.8kW
LOADING INFO: Gas hotplate
Natural
Gas
R.H.F
R.H.R
L.H.R.
L.H.F.
Heat Input
1.0kW
1.9kW
1.9kW
3.4kW
(3412 Btu/h)
(6483 Btu/h)
(6483 Btu/h)
(11600 Btu/h)
Injector marking
070
096
096
136
GENERAL
Ignition
(H.T.
Spark)
Spark Gap
3-4mm
GAS CATERGORY
COUNTRIES OF DESTINATION
CAT.
I
2H
GB
This appliance complies with: European Council Directives Low voltage
Directive73/23/EEC, Gas Directive 90/396EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68EEC. Energy Label Directive 2002/40/EC.