- 5 -
Spares Operation - R.Kurzke 02/05
599 521 951
EN
3.
Components
Interference Filter
The interference filter is connected in the terminal
board parallel to the mains feed.
Pressure Switch
The pressure switch controls the water level.
Without water, contact is closed.
fN
Switch point with level
45 mm Ws
Reset point with level
10 mm Ws
The pressure switch is not adjustable.
Flow Heater
The flow heater heats the water to the required temperature.
During the wash cycle, water is contantly passing through the
flow heater.
Power output
1100 W
Resistor
45
Ω
Protector
98 °C ± 5 K
Thermal fuse
260 °C