- 21 -
Spares Operation - R.Kurzke 02/05
599 521 951
EN
Service tips
Replacement of the components within the door.
Remove the screws from the frame.
Carefully unclip the front of the door.
Before finally opening, unclip the on/off LED.
The electronics can then be
snapped out.
You need
screwdriver
Torx TX20
The dosing unit is held by
screws.
After removing these screws, the
components can be removed
from the door breech.
Re-assembly is carried out in the
reverse order.
After removing the spring, the
door-opener can be removed
from its hinges.