5.13 Power management
• All cooking zones are connected to
one phase. See the illustration.
• The function activates when the total
electricity loading of the cooking
zones exceeds maximum electricity
loading of the phase.
• The function divides the power
between cooking zones.
• The function decreases the power to
the other cooking zones.
• The heat setting display of the
reduced zones alternates between the
chosen heat setting and the reduced
heat setting. After some time the heat
setting display of the reduced zones
stays on the reduced heat setting.
5.14 Hob²Hood
It is an advanced automatic function
which connects the hob to a special
hood. Both the hob and the hood have
an infrared signal communicator. Speed
of the fan is defined automatically on
basis of mode setting and temperature of
the hottest cookware on the hob. You
can also operate the fan from the hob
manually.
For most of the hoods the
remote system is originally
deactivated. Activate it
before you use the function.
For more information refer to
hood user manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of
the fan.
Automatic modes
Auto‐
matic
light
Boil‐
ing1)
Frying2)
Mode
H0
Off
Off
Off
Mode
H1
On
Off
Off
Mode
H2 3)
On
Fan
speed 1
Fan
speed 1
Mode
H3
On
Off
Fan
speed 1
Mode
H4
On
Fan
speed 1
Fan
speed 1
Mode
H5
On
Fan
speed 1
Fan
speed 2
Mode
H6
On
Fan
speed 2
Fan
speed 3
1) The hob detects the boiling process and
activates fan speed in accordance with au‐
tomatic mode.
2) The hob detects the frying process and
activates fan speed in accordance with au‐
tomatic mode.
3) This mode activates the fan and the light
and does not rely on the temperature.
Changing the automatic mode
1. Deactivate the appliance.
2. Touch for 3 seconds. The display
comes on and goes off.
3. Touch for 3 seconds.
4. Touch a few times until comes
on.
5. Touch of the Timer to select an
automatic mode.
To operate the hood directly
on the hood panel deactivate
the automatic mode of the
function.