TSE-P 02.00 EB
37/60
599 35 24-30
5.6 Circulation
pump
In Jetsystem models, the circulation pump is powered directly by the main PCB via a TRIAC.
5.7 Heating
The heating element is powered directly by the main PCB via a relay.
As a safety feature, a traditional dual-level pressure switch (anti-boiling 1 and anti-boiling 2) is connected in
series to the heating element.
The temperature is controlled directly by the main PCB via an NTC temperature sensor. Two versions of the
NTC sensor exist, depending on the type of tub; their shape is different, but their characteristics are
identical.
1. Plastic
casing
2. Metallic
capsule
3. NTC
resistor
4. Terminals
1. NTC
resistor
2. Metallic
capsule
3. Terminals
4. Plastic casing
RESISTANCE (
Ω
)
TEMPERATURE
(ºC)
Rated
Maximum
Minimum
20
60
80
6050
1250
640
6335
1278
620
5765
1222
660
5.8 Drain
cycle