(595889300 – ENG)
AOS101G
CAVITY BURNER
Parameters
GAS Injector
OFFSET
(hPa)
Aerator
StcA hAcA FucA
G20 7.00 Red -
0.25 80
26
100
G25 8.00 Red -
0.25 80
26
100
LPG2/30
5.50
Red
- 0.07÷ 0.00
23
26
100
LPG1
5.70
Red - 0.15÷ - 0.08 23
26
100
BOILER BURNER
Parameters
GAS Injector
OFFSET
(hPa)
Aerator
Stbo hAbo Fubo
G20 7.00 Red -
0.10 50
50
100
G25 8.00 Red -
0.10 40
50
100
G30
5.70
Red
- 0.28
33
45
74
LPG 5.70 Red -
0.15 33
45
74
LPG conversion for cavity burner for AOS101G
For LPG installations, put the ø 21 flow reducer flange between cavity burner fan and cavity burner. Change
the PWM parameters.
Then change the injector with the 5.70 one and calibrate the offset in the range - 0.15 ÷ - 0.08 hPa so as to
eliminate possible whistles/noises (row LPG1). After you have found the best working condition, cool down
and verify ignitions with cold burner.
If the previous setting does not eliminate whistles or noise, change the 5.70 injector with the 5.50 one and
use the calibrations of LPG2/G30 row: calibrate the offset in the range - 0.07 ÷ 0.00 hPa so as to eliminate
possible whistles/noises (row LPG1). After you have found the best working condition, cool down and verify
ignitions with cold burner.