Page 10
www.stoddart.com.au
Information and Error Codes
Information Codes
Error Codes
•
These codes may appear on the display
•
Codes indicating a value, function or state
•
These codes may appear on the display.
•
Codes indicating the need to contact the Stoddart Service Department
•
If an error code is displayed during a cooking cycle, the oven emits a continuous audible warning signal and the cooking cycle is interrupted.
•
In this case the oven can be used only in cooking modes that do not involve the conditions that generated the error.
•
Notify the Stoddart Service Department of the alarm code displayed.
Error Code
Error Code Description
EH20
Water supply pressure too low for CLEANING SYSTEM (pressure requirements from 1.5 to 2.5 bar)
EFUN
Fan automatic reset thermal switch device. UP appears on the small DISPLAY with reference to the single fan (6-10GN)
or upper fan (20 GN) of the chamber and DO in reference to the lower fan (only 20 GN)
E---
Non-compliance with a parameter requirement (number of parameter appears in place of dashes “---”)
EPt1
Chamber sensor interrupted or short-circuited
EPt2
Boiler sensor interrupted or short-circuited
EPt3
Probe sensor interrupted or short-circuited
EPt4
Bypass sensor interrupted or short-circuited
EPt8
Electronic controller temperature sensor damaged
ESCH
Malfunction of commands control circuit cooling devices
Etub
Boiler over temperature (125°C) warning
Etuc
Chamber over temperature (320°C) warning
EFLP
Fault in chamber steam discharge motor-operated valve
ETC
Tripping of chamber temperature limiter.
ETB
Tripping of boiler temperature limiter
Information
Code
Information Code Description
Cln
Cleaning system program switched on
Clnt
Semiautomatic cleaning program switched on
cont
Unlimited time setting
cool
Oven cooling on
ECLO
Clock error appears if the time has never been adjusted. To eliminate the error set the time
End
End of a cycle function
Fill
Boiler filling. (Ensure water supply isolation valve is open)
LOAd
Place the food in the oven
oPEn
Boiler discharge valve opening
PrEH
(Time TM / PRB DISPLAY) Boiler Preheating.
(COMPARTMENT TEMP. DISPLAY TS) Automatic compartment preheating
Soap
Spray undiluted oven cleaner onto soiled areas as per Page 3 Daily Cleaning Step 2
Strt
Press the START button to start the program
Stby
CLEANING SYSTEM - Cleaning standby time