14
Connection
Carry out the connection to the gas plant only by means of a rigid metallic pipe
conforming to the regulations in force.
This appliance is not suitable for connection with a hose assembly.
The joint for the entry of gas into the appliance is threaded R 1/2" (male thread).
Carry out the connection avoiding any type of stress on the appliance.
It is important to install the elbow correctly, with the shoulder on the end of the
thread, fitted to the hob connecting pipe.
Failure to ensure the correct assembly
will cause leakage of gas.
Natural gas appliances must be fitted with a pressure regulator and be installed
at the inlet connection. The gas pressure must then be set as a part of the
commissioning procedures.
For U-LPG the pressure adjustment is made via the regulator fitted at the domestic
cylinder. The natural gas regulator and U-LPG pressure test point must be accessible
with the appliance installed.
Important
Upon completion of installation, always check:
• that all the joints are completely sealed by using a soapy solution, never a
flame;
• that the gas pressure has been regulated to 1.00kPa for Natural Gas and 2.75kPa
for Universal-LPG. The pressure test point is located on the regulator. The pressure
should be measured and adjusted with the Wok burner on high flame;
• that the automatic ignition system is operating satisfactory on all burners, both
individually and in combination;
• that the burners operate correctly, are stable, without yellow tipping or excessive
noise on high and low flame.
Then demonstrate to the customer the appliance operation and leave
these instructions.
A)
End of shaft
with nut
B)
Washer
C)
Elbow
Installation