- 24 -
TSE-N 01.01 A. B.
599 50 86 62EN
6.2 Pyrolysis
Fig. Heating up curve temperature/time
P1: Heating time 150 min = pyrolysis 1
P2: Heating time 90 min = pyrolysis 2
Door locks at 312 °C, after 11 min
Door unlocks at 204 °C, after 120 min (P2) or 180 min (P1)
Centre of load 472 °C ± 5 °C
The cooling fan is operated at high speed until the time of unlocking then at a lower speed.
It switches off at approx. 130 °C residual heat in the muffle.