background image

  

1

-8-08

Recommended Table Connection and Fabrication

 

Warewashing

 

66

 Single Tank Conveyor Dishwasher

without 

B

uilt 

I

H

ot 

W

ater 

B

ooster WT66

The company reserves the right to make modifications to the products without prior notice.
All information correct at time of printing.

 

Warewashing

 

66

″″″″″

 Single Tank Conveyor Dishwasher

without 

B

uilt 

I

H

ot 

W

ater 

B

ooster WT66

1.50

38 mm

2.25

57 mm

1.75

45 mm

45 mm 45 mm

20.75

527 mm

INSIDE TANK

540 mm

OPENING

0.75

19 mm

8.00

203 mm

0.88

23 mm

2 HOLES 
FOR BOLTING
TABLE TO TANK

CENTER LINE

 MA

CHINE

FRONT OF

MACHINE

HOLE LOCATIONS IN TURNED DOWN

PORTION OF TABLE                   

21.25

1.75

1.75

AWG

20.75

/527 mm

INSIDE T

ANK

21.00

/533 mm

OPENING

1.75

45 mm

2.25

57 mm

AWG

8.00

203 mm

1.50

38 mm

8.25

210 mm

1.50

38 mm

0.63

16 mm

TRACK AND TABLE MUST
BE AT SAME LEVEL

USE SEALANT BETWEEN TABLE AND LIP       

OF TANK TO PREVENT WATER LEAKAGE

SECTIONAL VIEW SHOWING

TABLE CONNECTIONS

27.75

705 mm

21.25

540 mm

10.63

270 mm

8.25

210 mm

0.25

7 mm

CENTER LINE

MACHINE

AVG INSIDE

TABLE WIDTH

OPENING

FRONT OF 

MACHINE

0.25

7 mm

82.00

2083 mm

OVERALL

66.00

1676 mm

TABLE TO TABLE

4.00

102 mm

4.00

102 mm

74.00

1880 mm

16.00

406 mm

21.25

540 mm

OPENING

27.75

705 mm

32.06

814 mm

2.00

52 mm

CENTER LINE MACHINE

8.00

204 mm

34.00

865 mm

RACK RAIL 

HEIGHT

69.38

1761 mm

OVERALL

7.50

189 mm

20.00

508 mm

SERVICE CLEARANCE

(BOTH SIDES)

82.00

2083 mm

8.00

204 mm

Summary of Contents for 534094

Page 1: ...ons allow unrestricted all round access to the wash and rinse area Door is insulated with injected foam This adds strength as well as reduces noise and heat loss Large filters sloping towards the front to the smaller pressed filter box for quick removal Filters feature holes smaller than the concave ant block wash nozzles so large food cannot enter and block the wash system Filters easy to remove ...

Page 2: ...r requirements 26 gal 100 liters Initial fill Cold Water requirements 11 8 gal 45 liters Supply voltage 534094 WT66CL208 208 V 3p 60Hz 534095 WT66CR208 208 V 3p 60Hz 534096 WT66CL240 240 V 3p 60Hz 534097 WT66CR240 240 V 3p 60Hz Machine requires one electrical connection Max Current absorbed 208 V 3p 60Hz 64A 21 kW 240 V 3p 60Hz 57 5A 21 kW Exhaust Requirements Unit supplied as standard with extend...

Page 3: ... mm Min 15 75 204 mm 8 06 102 mm 4 00 177 mm 7 00 566 mm 22 25 623 mm 24 50 698 mm 27 50 200 mm 7 88 1037 mm 40 81 562 mm 22 13 578 mm 22 75 205 mm 8 06 D DE DE1 Water drain Detergent Dispenser Connection Detergent Probe EC1 EC2 CW Electrical connection 1 Electrical connection 2 Cold Water Inlet DE1 174 mm 6 81 562 mm 22 13 60 mm 2 38 50 mm 1 94 116 mm 4 56 209 mm 8 19 406 mm 16 00 592 mm 23 31 87...

Page 4: ...OWN PORTION OF TABLE 21 25 1 75 1 75 AWG 20 75 527 mm INSIDE TANK 21 00 533 mm OPENING 1 75 45 mm 2 25 57 mm AWG 8 00 203 mm 1 50 38 mm 8 25 210 mm 1 50 38 mm 0 63 16 mm TRACK AND TABLE MUST BE AT SAME LEVEL USE SEALANT BETWEEN TABLE AND LIP OF TANK TO PREVENT WATER LEAKAGE SECTIONAL VIEW SHOWING TABLE CONNECTIONS 27 75 705 mm 21 25 540 mm 10 63 270 mm 8 25 210 mm 0 25 7 mm CENTER LINE MACHINE AVG...