background image

Electric

Key Information

Water

 

Warewashing

 

44

 Single Tank Conveyor Dishwasher

with 

B

uilt 

I

H

ot 

W

ater 

B

ooster WT44

Supply voltage:

534070

208 V/3p/60Hz

534071

208 V/3p/60Hz

534072

240 V/3p/60Hz

534073

240 V/3p/60Hz

Dishwasher has three selectable hot water booster configurations
according to inlet water supply temperature.

Dishwasher requires two separate electrical service connections.
Connection 1 for Hot Water Booster; Connection 2 for running of the
machine (wash pump, tank heat, conveyor drive motor, rinse booster
pump, electronic control). Refer to the information below for Amp
requirements.

Booster 40 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

33.35A (12 kW)

240 V/3p/60Hz

28.9A (12 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load:

208 V/3p/60Hz

95A (33 kW)

240 V/3p/60Hz

83.9A (33 kW)

Booster 70 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

50A (18 kW)

240 V/3p/60Hz

43.3A (18 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load:

208 V/3p/60Hz

111.6A (39 kW)

240 V/3p/60Hz

98.3A (39 kW)

Booster 100 °F rise Electrical Characteristics

Hot Water Booster Amp Load Connection 1:

208 V/3p/60Hz

66.6A (24 kW)

240 V/3p/60Hz

57.7A (24 kW)

Wash Pump, Tank heat Amp Load Connection 2:

208 V/3p/60Hz

61.7A (21 kW)

240 V/3p/60Hz

55A (21 kW)

Total Amp Load:

208 V/3p/60Hz

128.3A (45 kW)

240 V/3p/60Hz

112.7A (45 kW)

Inlet Water supply pressure:

22 – 102 psi (150 – 700 kPa)

Inlet Water supply temperature
(booster size can be set on
site

 

during installation):

140 °F (60 °C)
with booster set as 40 °F rise.
110 °F (44 °C)
with booster set as 70 °F rise.
80 °F (27 °C)
with booster set as 100 °F rise.

Inlet Water supply hardness:

          4-8 gpg

 (7-14 °fH) max

Incoming water line size:

G 3/4

NOTE:

Two Hot Water Inlets on machine can be fed by
one incoming Hot Water line.

Drain line size:

G 1-1/2

Water consumption: Gallons/hr:

79.25 gal/hr (300 liters)

Water consumption/rack:

0.4 gal/rack (1.5 l/rack)

Wash Temperature:

160 – 172 °F (71-78 °C)

Wash tank size:

26 gal (100 liters)

Wash pump power:

2 hp (1.5 kW)

Wash pump water flow:

118.9 gal/min (450 l/min)

Rinse Temperature:

180 – 194 °F (82-90 °C)

Rinse pump power:

0.4 hp (0.32 kW)

Rinse pump water flow:

1.32 gal/min (5 l/min)

Hot water booster capacity:

6.2 gal (24 liters)

Initial fill water requirements:

32.2 gal (124 liters)

Productivity racks per hour

200 racks / 3600 dishes

(max speed):

(average 18 dishes per rack)

Productivity racks per hour

130 racks / 2340 dishes

(min speed):

(average 18 dishes per rack)

Table to Table connection:

44

 (1118 mm)

Number of Tanks:

1

Height with door open:

83-7/16

 (2119 mm)

Charging hole size (width):

20-7/8

 (530 mm)

Charging hole size (height):

19-3/4

 (501 mm)

Net weight:

1012 lb (459 kg)

Shipping weight:

1210 lb (549 kg)

Shipping width:

74-7/16

 (1890 mm)

Shipping depth:

40-15/16

 (1040 mm)

Shipping height:

81-1/8

 (2060 mm)

Shipping volume:

143 cu.ft (4.05 m

3

)

Noise level:

<70 dBA

Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.

Exhaust Requirements

Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 177 CFM (300 m³/h)
Refer to installation diagram for minimum exhaust hood
installation height .

Summary of Contents for 534070

Page 1: ... F incoming water temperature 70 F rise 110 F incoming water temperature or 100 F rise 80 F incoming water temperature Atmospheric booster system with air break Built in rinse hot water booster pump guarantees constant rinse pressure Speed of conveyor can be set through the control panel by the operator 130 racks hr or 200 racks hr Large counter balanced inspection doors allow unrestricted all rou...

Page 2: ... Inlet Water supply temperature booster size can be set on site during installation 140 F 60 C with booster set as 40 F rise 110 F 44 C with booster set as 70 F rise 80 F 27 C with booster set as 100 F rise Inlet Water supply hardness 4 8 gpg 7 14 fH max Incoming water line size G 3 4 NOTE Two Hot Water Inlets on machine can be fed by one incoming Hot Water line Drain line size G 1 1 2 Water consu...

Page 3: ...2 Min 400 mm Min 15 75 204 mm 8 06 102 mm 4 00 177 mm 7 00 566 mm 22 25 73 mm 2 88 623 mm 24 50 698 mm 27 50 200 mm 7 88 1037 mm 40 81 92 mm 3 63 562 mm 22 13 578 mm 22 75 1124 mm 44 25 205 mm 8 06 D DE DE1 Water drain Detergent Dispenser Connection Detergent Probe EC1 EC2 Electrical connection 1 Electrical connection 2 DE1 205 mm 8 06 174 mm 6 81 562 mm 22 13 60 mm 2 38 50 mm 1 94 116 mm 4 56 209...

Page 4: ...N PORTION OF TABLE 21 25 1 75 1 75 AWG 20 75 527 mm INSIDE TANK 21 00 533 mm OPENING 1 75 45 mm 2 25 57 mm AWG 8 00 203 mm 1 50 38 mm 8 25 210 mm 1 50 38 mm 0 63 16 mm TRACK AND TABLE MUST BE AT SAME LEVEL USE SEALANT BETWEEN TABLE AND LIP OF TANK TO PREVENT WATER LEAKAGE SECTIONAL VIEW SHOWING TABLE CONNECTIONS 27 75 705 mm 21 25 540 mm 10 63 270 mm 8 25 210 mm 0 25 7 mm CENTER LINE MACHINE AVG I...