17
Countertop models (Only for N9E range)
1. See the installation diagram for the position of the gas
connection on the bottom of the appliance.
2. Remove the plastic cap protection (if present) from the
gas manifold before connecting.
3. Countertop models can be connected to the gas supply
also using the rear connection:
a. operate at the back appliance;
b. unscrew the metal closing plug of the rear connection;
c. screw it tightly onto the bottom connection.
After installation, use soapy water to check connections for
leaks.
NOTE!
Only for Australia
: The gas connection is male 1/
2 BSP.
E.6.5
Gas pressure regulator
The section of the gas supply line must be sufficient to ensure
the gas flow necessary for full operation of all the appliances
connected to the system.
If the gas pressure is higher than that specified or is difficult to
regulate (not stable), install a gas pressure regulator (acces-
sory code 927225) in an easily accessed position ahead of the
appliance.
The pressure regulator should preferably be fitted horizontally,
to ensure the right outlet pressure.
1
connection side gas from mains
2
pressure regulator
3
connection side gas towards the appliance
The arrow on the regulator
indicates the gas
flow direction.
For Australia
: Adjust the test point pressure with burners
operating at maximum setting (see table “B“ of Appendix)
E.6.6
Conversion to another type of gas
Nozzle Table “B“ (see Appendix) gives the type of nozzles to
be used when replacing those installed by the manufacturer
(the number is engraved on the nozzle body).
At the end of the procedure, carry out the following check-list:
1. burner nozzle/s replacement
2. correct adjustment of primary air supply to burner/s
3. pilot nozzle/s replacement
4. minimum flame screw/s replacement
5. correct adjustment pilot/s if necessary
6. correct adjustment of supply pressure (see technical data/
gas nozzles table)
7. apply sticker (supplied) with data of new gas type used
E.7
Gas appliances regulations
Valve — Fig. 1
Frytop burner — Fig. 2
Manometer — Fig. 3
Frytop pilot — Fig. 4
E.7.1
Supply pressure checking (all versions)
Make sure the appliance is suitable for the type of gas
available, according to that given on the dataplate (otherwise,
follow the instructions given in E.6.6
paragraph of this section).
The supply pressure must be measured while the appliance
operates, using a pressure gauge (min. 0.1 mbar).
1. Remove the control panel and retaining screw “N“ from
the pressure point (see Valve — Fig. 1)
2. Connect the manometer “O“ (see Manometer — Fig. 3);
3. Compare the value read on the manometer with that given
in Table “B“ (see Appendix).
4. If the manometer gives a reading outside the range of
values in Table “B“ (see Appendix), do not switch the
appliance on, consult the gas company.
E.7.2
Primary air checking
The primary air is correctly adjusted when the flame does not
float with the burner cold and there is no flareback with the
burner hot.
1. Undo screw “A“ (see Frytop burner — Fig. 2);
2. Position aerator “B“ at distance “H“ given in Table “B“ (see
Appendix);
3. Retighten screw “A“ and seal with paint.
E.7.3
Main burner nozzle replacement
1. Remove the control panel.
1