Dealer Installation Instructions

The HEPA systems can be used independently of any other equipment! The 
intake and outflow of the filtration system can be ducted into the same room 
to create a cleaner enviro ment almost anywhere. The intake or outflow can also 
be ducted elsewhere. The intake and outflow should be installed on opposite 
sides of the room; however, this varies according to your specific needs.

Preparation:

Here are some things to consider as you decide where to install the HEPA 
system independently of other systems.

Location:

• Make sure there is room to open the HEPA filter access panel for filter 

changes/inspections.

• Keep the HEPA system away from possible water damage
• Vibration pads will reduce vibration for installations where the unit is placed 

on the floor.

• Install HEPA System on floor or suspended platform. If the unit is suspended, 

screws must not penetrate through the cabinet. Make sure that you have 
the proper chains/straps joists and equipment to keep unit secure. 

Intake (Marked as ‘Air In’ on unit):

• Intake ducts should be installed near the floor for optimum airflow. 
  If space does not allow, then the inlet can be installed in the ceiling.
• Intake duct should be installed at least 6 ft. away from the outflow duct.
• Intake duct should be installed at opposite end of the room from the  

outflow duct(s) if in the same room.

• Diffusers are recommended to help distribute airflow evenly. 

Outflow (Marked as ‘Clean Air Out’ on unit):

• Outflow(s) should be installed in the ceiling away from any other air inlet(s)
• Room diffusers are recommended to help distribute airflow evenly in the 

occupied space.

Ducting

:

• If HEPA system is installed where inlet and outflow collars face down,  

metal elbows must be connected to both inlet and outflow collars.

• Each connection must be sealed with aluminum tape or mastic, including 

all vent connections.

• Installed duct runs should be as straight as possible (if the duct runs  

are too long, reduced CFM may result).

• If duct is exposed to unconditioned air, insulated flex duct is highly  

recommended.

Example of Single Room Stand Alone System Installation
For single rooms where increased filtration is desired such as a dedicated 
‘smoking room’.

Externally insulated flex duct can also be used for noise reduction purposes.
• For best indoor air quality, do not use ductboard or fiberglass inside of ducts.

Electricity:

• The unit must be plugged into a grounded 20V, 60Hz. outlet.

Required Materials for Installation of Unit: 
Items for 350 

Flex or rigid duct (length as required) 

8” round & 6” round 

Takeoffs 

One 8” & One 6” 

Diffusers

One 8” & One 6” 

Items for 675 

Flex or rigid duct (length as required) 

0” round & 8” round 

Takeoffs 

One 0” & One 8” 

Diffusers

One 8” & One 6” 

All Models 

Aluminum tape or mastic as required 

Misc. hanging materials - field provided 

NOTE: Be sure to review ‘Rules for Safe Installation and Operation’ on page 
 of this document before start-up of this unit.

Operation (350 & 675)

 Make sure that the unit is plugged into a grounded power source  

(20 Volt, 60 Hz).

2 For optimum performance, the HEPA system should operate with the 

indoor air handler/furnace blower on.

3 Turn the unit on by pressing the on/off button and the green power light  

will illuminate.

4 To turn the unit off, press the on/off button and the power indicator light will go out.

Filter Light Indicators

Your HEPA system is equipped with an electronic filter timer. This timer  
monitors the life expectancy of each filter in the unit. By default, the Pre-Filter, 
HEPA Filter and VOC Blanket lights will turn on when the unit is powered on.
5 Turn the unit off and see instructions for “filter removal” to determine if filter 

replacement is needed. See ‘Maintenance” on next page.

6 Once the filters have been checked or replaced, turn the unit back on and 

reset the control panel. To reset, press and hold the flashing filter button 
until the light is constant.

Air should be drawn from
location B if space is avail-
able, otherwise, use loca-
tion A.

A

B

HEPA System

Summary of Contents for 350 STEAMER HAND GUN

Page 1: ... particulates should not be in the building and allow 24 hours of operation for removal of particulates from occupied spaces before re entry Shipping and Packing List Package 1 of 1 contains 1 HEPA System 1 Complete Filter Set Packed inside Unit 1 Installation Kit 1 Installation Instructions this manual 1 Registration Card 1 Warranty Statement HEPA System Models Model 350 is designed to filter air...

Page 2: ...If air passes through the carbon filter before particulates are removed the surface of the carbon quickly gets covered with particulates rendering it ineffective at capturing chemicals and odors If particulates are removed from the air with a HEPA filter virtually the entire surface area of the carbon can be used to capture chemicals and odors This increases the efficiency and filter life of the c...

Page 3: ...A Cartridge Parts Inside Cabinet Filter Section Motor Impeller Filter Adapter threaded O Ring Parts Identification Filter parts identification Physical dimensions of unit E G C F A A A Filter Section Access Panel Air Intake Air Outflow Motor Section Access Panel B B D Model Unit A B C D E F G 350 14 5 36 8 27 25 692 7 875 200 5 875 149 8 5 216 3 76 2 51 675 14 5 368 27 25 692 9 875 251 7 875 200 6...

Page 4: ... space Ducting If HEPA system is installed where inlet and outflow collars face down metal elbows must be connected to both inlet and outflow collars Each connection must be sealed with aluminum tape or mastic including all take offs Installed duct runs should be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air externally insulate...

Page 5: ...air outflow of the HRV ERV should be Y connected to the additional return duct then connected to the inlet of the HEPA system The additional return duct if any should be installed at least 6 ft away from the outflow duct on the main return Duct both the HRV ERV and the additional return into the intake of the HEPA system Outflow Marked as Clean Air Out on unit Outflow duct should be installed as c...

Page 6: ...ould be as straight as possible if the duct runs are too long reduced CFM may result If duct is exposed to unconditioned air insulated flex duct is highly recommended Example of Single Room Stand Alone System Installation For single rooms where increased filtration is desired such as a dedicated smoking room Externally insulated flex duct can also be used for noise reduction purposes For best indo...

Page 7: ... pre filter over time The color of the filter will change as particulates build up on the pre filter Change the pre filter when you can see the particulate build up start to clog up the pre filter HEPA Filter As the HEPA filter captures particulates it will darken over time Replace the HEPA filter when it darkens to the level seen in example D Inner Carbon Filter The inner carbon filter will rarel...

Page 8: ...rom the new inner carbon filter e Unroll the inner carbon filter and roll it up in the opposite direction this makes the filter follow a more contoured profile against the inner HEPA filter surfaces and helps keep it in place place the rolled inner carbon filter inside the HEPA cartridge and gently unroll it until the ends butt together and the filter is snug against the HEPA filter 4 HEPA Filter ...

Page 9: ...c c Connect the wires as follows Black wire from the Plug and Cable P12 to Line P3 on the CM71 Power Module Green wire from CM71 Power Module to the ground post Blue wire from motor to the Motor 2 P4 post on the CM71 Power Module Yellow green wire from motor to the ground post Brown wire from the motor to a Capacitor C10 post Black wire from the motor to the Motor 1 P2 post on the CM71 Power Modul...

Page 10: ...ke Collar 350 8 Exhaust Collar 350 6 Electronic Key Pad Electronic Switch Board Capacitor 350 O Ring Beam Model 675 Central HEPA Air Filtration System Replacement Filters HEPA Cartridge Replacement 15 Replacement HEPA for 350 675 Annual Filter Kit 15 Standard 1 Foam Prefilter 2 Carbon Inner Blanket for 350 675 Replacement Components For Beam Model 675 Central HEPA Air Filtration Systems Filter Cab...

Page 11: ...2 Bulk Head Model 350 172004 Model 675 172005 Motor Blower Model 350 172009 Model 675 172010 Motor Mount Model 350 172007 Model 675 172008 Base same for all models 172006 Cabinet Model 350 172002 Model 675 172003 Electronic Switch same for all models Key Pad 172014 Switch Board 172015 Capacitor Model 350 172016 Model 675 172017 Intake Collar Model 350 8 172012 Model 675 10 172011 Beam Central HEPA...