6 Connection of external dosing systems
6.1
Connection of the hoses
The machine is prepared for connection of external dosing systems or water re-use systems etc.
The connections are closed at delivery. Open any of the connections that shall be used by drilling a hole where the
hoses shall be connected.
Note!
Make sure there is no burrs left after drilling. When removing burrs make sure burrs does not fall into the si-
phon breaker.
A =
⌀
17 mm (used for external dosing systems or systems for re-use of water).
B =
⌀
6 mm (used for external dosing systems only).
C = Only used for external liquid manifold. (Separate instructions enclosed when ordering).
A
B
C
Always connect hoses on connections A with a hose clamp.
For connections B; if the hoses are made of a soft material such as silicone or similar, use a cable tie to fasten the
hose on the connection. If the hoses are made of a hard material, it is not recommended to make the connection
tighter by using a cable tie.
Note!
Equipment for external dosing must only be connected to work on pump pressure and not on network
pressure.
6.2
Electrical connection of external dosing system
The power supply to the external dosing system must never be connected to the machine’s incoming terminal
block or to the edge connectors on the I/O-board.