DOC
NUMBER
595R495
121
SERVICE MANUAL Blast Chiller Freezer 100 - 200
6.4.9 Thermostat
Steps for replacing the Thermostat:
88. Follow the procedure in the paragraph [
Opening the fan casing
].
89. Disconnect the thermostat connector and unscrew the sealing nut.
6.4.10 Cell probe
Steps for replacing the Cell probe:
90. Follow the procedure in the paragraph [
Opening the fan casing
].
91. Find the cell probe on the fan protection grid and cut the cable ties to release the probe (Fig. 1).
92. Remove the covering panel (P) by unscrewing the two screws (figure 2).
93. Disconnect the probe connector.