32
Installation manual
Liquied petro-
leum gases
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+
28-30 /
37
No regulation
1.35
No
490375693
BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane
3B/P
30, 37, 50
28
1.35
No
490375694
AT, BE, BG,
CH, CY, DE,
DK, EE, FI, FR,
GB, HR, HU,
IS, IT, LT, LU,
MT, NL, NO,
PL, RO, SE, SI,
SK, TR
Propane
3P
30, 37, 50
28
1.45
No
490375695
AT, BE, CH,
CZ, DE, ES, FI,
FR, GB, GR,
HR, IE, IT, LT,
LU, NL, PL, PT,
RO, SI, SK
Town gas
Gas category
Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (
⌀
mm)
Air reducing
plate (mm)
Label number
May be avail-
able in follow-
ing countries
1a
8
4.5
4.10
487042239
Default
DK, IT
1b
8
3.5
4.10
487042239
490376107
SE
When a machine shall be installed or used on high altitude (2001 feet and higher) a kit for high altitude must be
installed.
For kit No. please refer to the spare parts list.
7.5
Test run
• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
• Select a program with heat.
• Start the machine.
• Check the nozzle pressure, see “Table of pressure and adjustment”.
• If necessary adjust the regulator setting screw (4) behind the cover screw (3). Replace the cover screw (3) if
removed.
• Check that the gas is burning evenly. The blue flame on the burner is preferred.
• Tighten the screw (2) when the adjustments are done.
2
3, 4
fig.7120