18
Installation manual
7 Connection to floor drain
The drying cabinet comes with a preinstalled hose for connection to a floor drain. The hose connection if found on
both sides at the lower rear corner of the cabinet.
fig.W01408
• Connect a new drain hose to one of the cabinet connections and route it to the drain.
• If the floor drain is higher than the cabinet drain, make sure that the hose makes an arch down towards the floor
and forms a water trap. If you fail to do this, there is a risk of condensation flowing back to the box when the pump
is not running. This could cause the box to fill with water and the cabinet to stop working.
2
1
3
fig.W01409
1
Left side's drain hose
2
Right side's drain hose
3
Nipple
• Replace/check the drain side by moving the nipple drain hose on either the right or the left side.
The hoses from the dehumidifier units are delivered from the factory connected to the drain on the left side.
The hose must not under any circumstances be bent so much that the flow of water is obstructed